27
Error Codes
Error Fault
Action
Step
Combustion fan overcurrent. Unit
operates, then stops.
Check flue terminal for blockages
visual
10
Check Flue
V
Check combustion fan.
A
Check Gas Supply is correct
S
Check Gas Isolating Valves are open
visual
Check Electrode
B
Check Flame Rod
C
11 Missed or No Ignition. Unit stops
without flame igniting
Check Sparker
B
Check Solenoids
D
Check Gas Filter
F
Check Earth Wire
H
Check Flue
V
Check gas pressure
manual
Check injector manifold is correct for gas type
manual
Check Gas Type Dip Switches for Nat. Gas or LPG. manual
Check Gas Supply is correct
S
Check Gas Isolating Valves are open
visual
Check Flame Rod
C
Check Earth Wire
H
12 Flame Failure / Earth Leakage
Check Flue
V
Lost Ignition
Check Gas Filter
F
Check Gas Type Dip Switches for Nat. Gas or LPG. manual
Check gas pressure
manual
Check Remote control
I
14
Thermal Fuse and/or overheat
switch activated, unit operates,
then stops
Check Overheat Circuit
E
incl. Thermal Fuse (thermal overload wire)
E
incl. Overheat switch (black tophat style bi-metal)
E
Check Gas Type Dip Switches for Nat. Gas or LPG. manual
Check gas pressure
manual
Check combustion dip switch
manual
16
Over temp warning. Unit operates,
then stops.
Check Gas Type Dip Switches for Nat. Gas or LPG. manual
Check modulating solenoid valve
D
Check gas pressure
manual
Check combustion dip switch
manual
Check water flow sensor
J
Check water flow servo
G
Check Heat Ex outlet temperature thermistor
K
Check hot water outlet thermistor
K
32 Outlet water thermistor faulty
Check hot water outlet thermistor
K
34 Combustion air thermistor faulty
Check Combustion Air Thermistor.
K
61 Combustion Fan rotation error
Check combustion fan.
A
71 Solenoid valve circuit error. Unit
does not operate
Check Gas Valves are open
visual
Check Solenoids
D
72 Flame Rod Circuit Error. Unit
does not operate
Check Flame Rod
C
-
No combustion despite remote
control indicating that combustion
is occurring - if remote controllers
are installed
Check water flow sensor
J
Check Flame Rod
C
Check hot water outlet thermistor
K
Check combustion fan.
A
Check Sparker
B
Check Gas Valves are open
visual
Check Overheat Circuit
E
Summary of Contents for FUA-E
Page 1: ......
Page 5: ...5 Glossary of Terms and Symbols ...
Page 9: ...9 Dimensions ...
Page 11: ...11 Structure Diagram ...
Page 17: ...17 Gas Conversion Procedure ...
Page 18: ...18 Gas Conversion Procedure ...
Page 25: ...25 Operational Flow Chart ...
Page 26: ...26 Time Charts ...
Page 39: ...39 Diagnostic Checks Fault Finding Chart ...
Page 40: ...40 Fault Finding Chart ...
Page 41: ...41 Fault Finding Chart ...
Page 42: ...42 Fault Finding Chart ...
Page 43: ...43 Fault Finding Chart ...
Page 44: ...44 Fault Finding Chart ...
Page 45: ...45 Fault Finding Chart ...
Page 46: ...46 Wiring Diagram ...
Page 49: ...49 Dismantling for Service ...
Page 50: ...50 Dismantling for Service ...
Page 51: ...51 Dismantling for Service ...
Page 52: ...52 Dismantling for Service ...
Page 53: ...53 Dismantling for Service ...
Page 54: ...54 Dismantling for Service ...
Page 55: ...55 Dismantling for Service ...
Page 56: ...56 Exploded Diagram ...
Page 57: ...57 Exploded Diagram ...
Page 58: ...58 Exploded Diagram ...
Page 59: ...59 Exploded Diagram ...
Page 60: ...60 Exploded Diagram ...
Page 61: ...61 Parts List ...
Page 62: ...62 Parts List ...
Page 63: ...63 Parts List ...
Page 64: ...64 Parts List ...
Page 65: ...65 Letter of Compliance ...
Page 66: ...66 CE Certificate ...
Page 67: ......