EX08DT and EX11DT Installation and Operation Manual
15
Use this checklist to ensure you have selected the correct location for the direct vent furnace.
4.3.3 Installation Location Checklist
The furnace is not exposed to corrosive compounds in the air.
The furnace location complies with the required clearances.
The planned venting termination/air intake location meets the clearances.
Indoor air is not being used for combustion.
A standard 3 prong 120 VAC, 60 Hz properly grounded wall outlet is available.
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane
Installation Code, CSA B149.1. If installed in a manufactured home, the installation must
conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR,
Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes.
Leave the entire manual taped to the furnace or give the manual directly to the
consumer.