NOTES:

1.

If the furnace is equipped with NOx screens and is to be
used with LP (propane) gas, the screens must be removed
prior to start-up.

2.

Drip leg in the gas line must be installed.

3.

The furnace controls require correct polarity on the power
supply and a proper ground.

4.

Y & G must be connected to the control board for cooling
operation.

5.

External filters required on all configurations.

6.

Electrical or gas entry is available on both casing sides.

7.

To measure total static pressure add supply duct pressure to
the return duct pressure, add pressure drop across the ‘A’
coil, and add pressure drop across the filter. Ignore negative
signs on the readings.

8.

Inlet gas pressure for natural gas should be 7” and  for pro-
pane should be 11” w.c. Nominal manifold gas pressure is
3.5” for natural gas and 10” w.c. for propane at max. input.

9.

For downflow application the vent blower must be rotated 90
left or right as shown.

* Other airflows are available. see Tech guide for all CFM options.

LED INDICATOR

Slow Green Flash - Normal operation in standby mode

Slow Amber Flash - Normal operation with call for cooling

Two Amber Flashes - Normal operation with call for heat

Three Amber Flashes - Normal operation, burner is on at end of
thermostat cycle.

Six Amber Flashes - Normal operation with call for heat pump
heating.

Any Red Flash - Fault condition

Models

Airflow CFM (Bottom Return without Filters)

Minimum Wire

Size awg @ 75'

One-Way

Maximum

Over Current

Protection

0.5" ESP (Nominal)*

D-A

C-A

B-A

A-B

(T,Y,C,L)PLC060A12MP12C

600

815

1050

1340

14 15 

(T,Y,C,L)PLC080B12MP12C

580

775

960

1290

14 15 

(T,Y,C,L)PLC080C16MP12C

1000

1200

1395

1715

14 15 

(T,Y,C,L)PLC100C16MP12C

980

1165

1345

1600

14 15 

(T,Y,C,L)PLC100C20MP12C

1140

1330

1515

2110

12 20 

(T,Y,C,L)PLC120C20MP12C

1200

1400

1510

1990

12 20 

Models

Input 

Rate

Total Unit

Amps

Air Temp. Rise

Max Input °F

Air Temp. Rise

Min Input °F

Time For 1 ft

3

 Natural Gas  

(1030 Btu/Ft

3

) Seconds 

(On Max. Rate)

Max

Min

(T,Y,C,L)PLC060A12MP12C

60,000

30,000

7.0

30-60

20-50

62 

(T,Y,C,L)PLC080B12MP12C

80,000

40,000

7.5

40-70

20-50

46 

(T,Y,C,L)PLC080C16MP12C

80,000

40,000

10.0

35-65

20-50

46 

(T,Y,C,L)PLC100C16MP12C

100,000

50,000

10.0

35-65

20-50

37 

(T,Y,C,L)PLC100C20MP12C

100,000

50,000

12.0

35-65

20-50

37 

(T,Y,C,L)PLC120C20MP12C

120,000

60,000

12.0

45-75

25-55

30 

This document does not replace the installation instructions, which must be referred to for 
detailed information.

CLEARANCES

* 24" clearance in front and 18" on side recommended for 

service access.

All furnaces approved for alcove and attic installation.

DIMENSIONS

FRONT

A

SUPPLY END

RETURN END

LEFT SIDE

RIGHT SIDE

33”

Clips can be flipped
into the up position
for coil cabinet or
plenum attachment

A-COIL

Follow all national, local codes and standards in addition to this document. The installation
must comply with regulations of the serving gas supplier, local building, heating, plumbing,
and other codes. In absence of local codes, the installation must comply with the national
codes and all authorities having jurisdiction.

28.5”

Gas Pipe

Entry

Thermostat
Wiring

14”

1”

1.5”

23”

Electrical
Entry

.5”

.5”

B

24.25”

4” Diameter
Vent Connection
Outlet

24.38”

20”

.5”

B

.5”

Electrical
Entry

Vent

Connection

Outlet

29.5”

(For Cladded door add

appoximately an additional .75”)

Application

Upflow

Downflow

Horizontal

Top

1" 0" 0" 

B-Vent

1" 1" 1" 

Rear

0" 0" 0" 

Side

0" 0" 1" 

Front*

0" 0" 0" 

Floor

Combustible

Combustible

1

1. For combustible floors only when used with special 

sub-base.

Combustible

Closet

Yes

Yes

Yes

Line Contact

No

No

Yes

Cabinet Size 

A (in) 

B (in) 

All 'A' Cabinet Furnaces 

14-1/2" 

13-3/8" 

All 'B' Cabinet Furnaces 

17-1/2" 

16-3/8" 

All 'C' Cabinet Furnaces 

21" 

19-7/8" 

QUICK REFERENCE GUIDE

80% MODULATING ECM MULTI-POSITION 
RESIDENTAL GAS FURNACES (33” TALL)

Subject to change without notice. Published in U.S.A.

535679-URG-A-0909