1. UNPACKING THE APPLIANCE
The heater is supplied in one carton containing; Heater, Standard Rear Cover Set and Bolt Pack.
Remove all packaging materials. Check for damage. If
any
damage is evident
DO NOT
install or
operate this appliance. Contact your supplier for advice. Before installing the heater, check it is
labelled for the correct gas type, (refer to the data label at the rear of the heater). Refer to the local
gas authority for confirmation of gas type if you are in doubt.
The heater does not come supplied with flue components. These are
purchased separately.
ONLY Rinnai Energysaver
®
Co-Axial Flue System Flue components can be
used with this appliance.
240 VOLTS, RISK OF ELECTRICAL SHOCK!
Ensure the appliance is disconnected from mains power.
2. CONNECTING THE APPLIANCE TO THE CONSUMER GAS PIPE
1. Remove the plastic protection cap from the threaded gas inlet located at the rear of the appliance.
2. Position the appliance gas inlet in line with gas supply from wall.
3. Attach gas supply pipe to the appliance gas inlet and tighten - finger tight. Appliance has R1/2
fitting.
4. On the wall behind the appliance, at a level of about midway of the heaters height, mark the vertical
centre line of the heater.
5. Mark the flue penetration position in accordance with ‘Energysaver
®
Space Heater Co-Axial Flue
System Installation’ manual.
6. Undo the gas connection, remove the heater.
7. Cut Flue penetration(s)
8. Mark out the securing bracket screw holes in
accordance with the drawing adjacent and table
below using the centre line as reference.
9. Attach the two securing brackets supplied to the wall
using the two 8g x 30mm screws supplied, or suitable
equivalent.
10.Install flue system in accordance with ‘Energysaver
®
Space Heater Co-Axial Flue System
Installation manual’.
11. Return the heater to the final position.
NOTE
WARNING
A
B
C
L
Floor Level
Heater Centre Line
Securing brackets
Models
A = Width
B = Height
RHFE-556FTR 450
506
RHFE-556FDT 450
506
RHFE-557FTR 300
685
RHFE-1004FTR 500 622
RHFE-1004FDT 500 622
SECURING
BRACKET
HEATER INSTALLATION