Rinnai Australia
27
Energysaver® - Operation & Installation Manual
Models:
RHFE-556FTR
RHFE-556FDT
RHFE-557FTR
RHFE-1004FTR
RHFE-1004FDT
Type of Appliance
Energysaver® Fan Forced Power Flued Gas Space
Heater
Height (mm)
- Width
- Depth
- Height
750
250
554
750
250
554
930
330
670
Weight (Kg)
22
22
42
Input (MJ/hr) - Nat
Gas
- High
- Low
23
9
23
9
37
11
Gas Control
Rinnai Electronic Modulating Control
Burner
Stainless Steel Ribbon Type
Gas Inlet
R 1/2” Male Thread (15 mm)
TPP (kPa) - NG
- High
- Low
0.51
0.09
0.51
0.09
0.76
0.49
TPP (kPa) - LPG
- High
- Low
1.06
0.18
1.06
0.18
2.33
1.07
Flue
Forced Flue
Flue Connection
Supplied with heater
Flue Systems
All flue systems are sold separately to suit
individual applications
Ignition
Continuous electrical spark, direct to main burner
Electrical Supply
240 V, 50 Hz - The unit is fitted with a supply lead
and 3 pin plug, replace only with Rinnai part only.
Fan
Centrifugal 7 Speed Fan
Rinnai are continually updating and improving products, therefore specifications are subject to
change without prior notice.
SPECIFICATIONS