Rinnai Australia
34
Energysaver® - Operation & Installation Manual
Below are diagrams and associated dimension tables for wall penetrations for each Energysaver
heater models.
RHFE 556
RHFE 557
RHFE 1004
All dimension are in millimetres
RHFE 556 RHFE 557 RHFE 1004
i
Width of appliance
750
550
930
ii
Centre-Line of appliance
375
275
465
iii
Arc axis (Axis point of the flue elbow)
—
—
—
A
Horizontal distance from Centre-Line to arc centre
220
172
305
B
Vertical distance from base to arc centre
215
264
165
C
Minimum horizontal limit of arc
240
200
325
D
Minimum vertical limit of arc
215
264
250
E
Maximum vertical limit of arc
310
390
340
F
Maximum horizontal limit of arc
300
230
365
G
Penetration diameter
100
100
100
D
B
E
A
C
F
G
ii
I
iii
D
B
E
A
C
F
G
ii
i
iii
D
B
E
A
F
C
G
ii
i
iii
WALL PENETRATIONS