Rinnai Direct Vent Service Manual
85
RHFE-202FTA
RHFE-265FTA
Gas Pressure Setting Procedure
1. Turn off the gas and the power supply.
2. Remove the 5 screws that hold the louver assembly
and front panel. Lift the panel straight up and then
remove it.
3. Remove two pressure point screws (1/8 NPT tap) with
3/16 Allen wrench and attach the manometer to both
pressure points. Both pressure points must be used
in order to measure the differential pressure. Ensure
that the manometer is properly calibrated.
4. Turn on the gas and power supply to the appliance.
(Press the “Set back” button after turning on the
power supply.) With the unit in the off position, press
the test switch at the top of PC board until it beeps.
5. Select the correct code for gas type and altitude using
▲
and
▼
buttons. Refer to the table below.
CAUTION
Do not touch any other areas on the PC board besides
the switches while power is supplied to the appliance.
Parts of the PC board are supplied with 120 volts AC.
CAUTION
Do not touch the areas at or near the exhaust. These
areas become very hot and could cause burns.
Natural Gas
Propane Gas
Altitude
0-2000 ft
0-610 m
2001-5200 ft
611-1585 m
5201-7700 ft
1586-2347 m
7701-10200 ft
2348-3109 m
0-2000 ft
0-610 m
2001-5200 ft
611-1585 m
5201-7700 ft
1586-2347 m
7701-10200 ft
2348-3109 m
Manifold test
pressure -
W.C.
Low
0.58 in
(15 mm)
0.62 in
(16 mm)
0.70 in
(18 mm)
0.78 in
(20 mm)
0.86 in
(22 mm)
0.92 in
(24 mm)
1.04 in
(27 mm)
1.16 in
(29 mm)
Manifold test
pressure -
W.C.
High
3.4 in
(86 mm)
3.6 in
(92 mm)
4.1 in
(103 mm)
3.2 in
(82 mm)
5.8 in
(147 mm)
6.2 in
(158 mm)
7.0 in
(177 mm)
5.5 in
(140 mm)
EX11C
Manifold test
pressure -
W.C.
Low
0.60 in
(15 mm)
0.64 in
(16 mm)
0.72 in
(19 mm)
0.80 in
(20 mm)
1.06 in
(27 mm)
1.16 in
(29 mm)
1.28 in
(33 mm)
1.41 in
(36 mm)
Manifold test
pressure -
W.C.
High
2.2 in
(56 mm)
1.9 in
(49 mm)
1.7 in
(44 mm)
1.6 in
(40 mm)
3.8 in
(95 mm)
3.3 in
(84 mm)
3.0 in
(75 mm)
2.7 in
(69 mm)
EX08C
Code
A1 / A5 *
A2 / A6 *
A3 / A7 *
A4 /A8 *
L1 / L5
L2 / L6
L3 / L7
L4 / L8
Pressure
Point
Pressure
Point
Nozzle Manifold
Test Switch
PC Board
* For the EX11C with natural gas: Use A1, A2, A3, or A4 for venting up to 7 feet (2.1 m) with one elbow.
Use A5, A6, A7, or A8 for venting exceeding 7 feet (2.1 m) with one elbow.
Summary of Contents for Energysaver RHFE-1004FTA
Page 14: ...14 Rinnai Direct Vent Service Manual RHFE 201FA RHFE 201RFA Wire Diagram ...
Page 15: ...Rinnai Direct Vent Service Manual 15 RHFE 201FA RHFE 201RFA Ladder Diagram ...
Page 18: ...18 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII RHFE 263RFA Wire Diagram ...
Page 19: ...Rinnai Direct Vent Service Manual 19 Ladder Diagram RHFE 263FA RHFE 263FAII RHFE 263RFA ...
Page 26: ...26 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Page 27: ...Rinnai Direct Vent Service Manual 27 RHFE 556FAIII Wire Diagram ...
Page 28: ...28 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Page 32: ...32 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Page 33: ...Rinnai Direct Vent Service Manual 33 RHFE 556WTA Wire Diagram ...
Page 45: ...Rinnai Direct Vent Service Manual 45 RHFE 551FA Fault Finding Summary ...
Page 46: ...46 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 1 ...
Page 47: ...Rinnai Direct Vent Service Manual 47 RHFE 551FA Fault Finding Chart 2 ...
Page 48: ...48 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 3 ...
Page 49: ...Rinnai Direct Vent Service Manual 49 RHFE 551FA Fault Finding Chart 4 ...
Page 50: ...50 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 5 ...
Page 51: ...Rinnai Direct Vent Service Manual 51 RHFE 551FA Fault Finding Chart 6 ...
Page 52: ...52 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 7 ...
Page 53: ...Rinnai Direct Vent Service Manual 53 RHFE 551FA Fault Finding Chart 8 ...
Page 54: ...54 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 9 and 10 ...
Page 55: ...Rinnai Direct Vent Service Manual 55 RHFE 551FA Wire Diagram ...
Page 58: ...58 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Page 59: ...Rinnai Direct Vent Service Manual 59 RHFE 1001FA Fault Finding Chart ...
Page 60: ...60 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Page 61: ...Rinnai Direct Vent Service Manual 61 RHFE 1001FA Wire Diagram ...
Page 64: ...64 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Page 65: ...Rinnai Direct Vent Service Manual 65 RHFE1001FA VA Fault Finding Chart ...
Page 66: ...66 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Page 67: ...Rinnai Direct Vent Service Manual 67 RHFE1001FA VA Fault Finding Chart ...
Page 68: ...68 Rinnai Direct Vent Service Manual RHFE 1001FA VA Wire Diagram Wire Diagram Ladder Diagram ...
Page 73: ...Rinnai Direct Vent Service Manual 73 RHFE 1004FA RHFE 1004RFA RHFE 1004FTA Wire Diagram ...