Rinnai Direct Vent Service Manual
105
1. Plug unit up to the power supply circuit.
2. Now with the unit in the
“Off”
mode press the
“UP”
button first and then press the
“Test Switch”
. This will
enter the unit into the programming mode.
3. To begin programming your desired temperature limit set point, press the
“Up”
or
“Down”
temperature
adjustment button on the control panel until you have achieved your set point. Once you have select your
maximum temperature set point, press the
“Test Switch”
once, this locks in your maximum operating
temperature at the temperature you selected.
Temperature set point limits are - (H) high fire, 80, 78, 76, 74, 72, 70. The unit will limit its operating
temperature to one of the set points above, based on your selection.
RHFE-1004FA (using propane)
Harmonic Noise
On occasion, a whistling noise may come from the RHFE-1004FA using propane gas. This harmonic noise can
be attributed to varying gas compositions and is more prevalent on new tank sets that may still have high traces of
methanol in the system. The adjustments recommended are not detrimental to the operation of the appliance in
any way.
PROCEDURE:
1. Perform the Gas Pressure Setting Procedure. During this procedure, set the low fire manifold gas pressure to
3.9” W.C. and the high fire manifold gas pressure to 9.8” W.C.
2. After performing the above procedure, set the low fire burner air shutter to three notches. This adjustment rod
can be found on the right hand front burner just under the gas line where it enters the combustion chamber.
Loosen the set screw in the brass slide and slide the shutter rod out to the third notch.
Setting a Maximum Temperature
RHFE-263FA/FAII, RHFE431WTA, RHFE-556WTA, RHFE-1004FA
The ENERGYSAVER
®
models below have the ability to set a maximum temperature limit directly from the control
panel. This is beneficial to landlords and property management for conserving energy and reducing unnecessary
gas consumption.
Procedure for Setting Maximum Temperature Limit on ENERGYSAVER
®
Furnaces
RFA Models:
ES08, ES11, ES17, ES22
FTA Models:
EX08C, EX11C, EX17C, EX22C
WTA Models:
EX17, EX22
RFA and FTA Model:
ES38
1. While the unit is off, press the
“Function Lock” or “Child Lock”
and “Up” arrow buttons at the
same time for about 3 seconds
until the unit beeps.
1. While the unit is off, press the
“Economy” and “Select” buttons
at the same time for about 3
seconds until the unit beeps.
1. While the unit is off, press the
“Economy” and “up” buttons at
the same time for about 3
seconds until the unit beeps.
2. Select the maximum temperature with the up and down buttons.
3. Press the On/Off button to save the new setting.
Summary of Contents for Energysaver RHFE-1004FTA
Page 14: ...14 Rinnai Direct Vent Service Manual RHFE 201FA RHFE 201RFA Wire Diagram ...
Page 15: ...Rinnai Direct Vent Service Manual 15 RHFE 201FA RHFE 201RFA Ladder Diagram ...
Page 18: ...18 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII RHFE 263RFA Wire Diagram ...
Page 19: ...Rinnai Direct Vent Service Manual 19 Ladder Diagram RHFE 263FA RHFE 263FAII RHFE 263RFA ...
Page 26: ...26 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Page 27: ...Rinnai Direct Vent Service Manual 27 RHFE 556FAIII Wire Diagram ...
Page 28: ...28 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Page 32: ...32 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Page 33: ...Rinnai Direct Vent Service Manual 33 RHFE 556WTA Wire Diagram ...
Page 45: ...Rinnai Direct Vent Service Manual 45 RHFE 551FA Fault Finding Summary ...
Page 46: ...46 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 1 ...
Page 47: ...Rinnai Direct Vent Service Manual 47 RHFE 551FA Fault Finding Chart 2 ...
Page 48: ...48 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 3 ...
Page 49: ...Rinnai Direct Vent Service Manual 49 RHFE 551FA Fault Finding Chart 4 ...
Page 50: ...50 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 5 ...
Page 51: ...Rinnai Direct Vent Service Manual 51 RHFE 551FA Fault Finding Chart 6 ...
Page 52: ...52 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 7 ...
Page 53: ...Rinnai Direct Vent Service Manual 53 RHFE 551FA Fault Finding Chart 8 ...
Page 54: ...54 Rinnai Direct Vent Service Manual RHFE 551FA Fault Finding Chart 9 and 10 ...
Page 55: ...Rinnai Direct Vent Service Manual 55 RHFE 551FA Wire Diagram ...
Page 58: ...58 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Page 59: ...Rinnai Direct Vent Service Manual 59 RHFE 1001FA Fault Finding Chart ...
Page 60: ...60 Rinnai Direct Vent Service Manual RHFE 1001FA Fault Finding Chart ...
Page 61: ...Rinnai Direct Vent Service Manual 61 RHFE 1001FA Wire Diagram ...
Page 64: ...64 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Page 65: ...Rinnai Direct Vent Service Manual 65 RHFE1001FA VA Fault Finding Chart ...
Page 66: ...66 Rinnai Direct Vent Service Manual RHFE1001FA VA Fault Finding Chart ...
Page 67: ...Rinnai Direct Vent Service Manual 67 RHFE1001FA VA Fault Finding Chart ...
Page 68: ...68 Rinnai Direct Vent Service Manual RHFE 1001FA VA Wire Diagram Wire Diagram Ladder Diagram ...
Page 73: ...Rinnai Direct Vent Service Manual 73 RHFE 1004FA RHFE 1004RFA RHFE 1004FTA Wire Diagram ...