Ember Installation Guide: 12890-B 02-18
Dimensions are in mm unless otherwise stated
8 m maximum
590
Unit height
Vertical and horizontal termination (masonry only)
Flueing options
900 min.
590
Unit height
400
1200 max.
Vertical termination flue component
Masonry chimney flexi vertical flue kit (R3652)—actual chimney size needs to be at least
200 x 200 mm for the flexi flues to fit down the chimney.
Horizontal termination flue components
1. Ember adaptor (R3653), stretches out to 1.2 m
2. Masonry horizontal flue box (R2449)
3. Horizontal wall terminal (R3650)
These flueing options are available for non-combustible openings only.
Flue kits and components
Mock chimney vertical flue kit 3.6 m
Code: R3665
Coaxial vertical flue kit
that attaches to the Ember
Adaptor.
Kit includes; high wind roof
cowl, flue pipes 1200 mm x 3,
wall straps x 3.
If longer flueing is required,
order additional flue pipes.
Masonry chimney flexi vertical flue kit
Code: R3652
For installation into a masonry fireplace. Allows
the fire to perform more effectively by achieving a
better draw. Extends out to 8 m.
Kit includes; flue cowl, chimney flashing plate,
intake flexi
Ø
75 mm (LHS), exhaust flexi
Ø
100 mm
(RHS).
455 mm
455 mm
Mock chimney horizontal flue kit
Code: R3654
Coaxial horizontal flue kit that attaches to the
Ember Adaptor.
If longer flueing is required order additional flue
pipes.
90 ° bend
300 mm
flue pipe
Horiz.wall
terminal
Horiz.
flashing
kit
Masonry horizontal flue box
Code: R2449
Horizontal flue box that joins the Ember
adaptor to the horizontal wall terminal. Used in
installations where the chimney has been capped
off. Refer previous page for detail drawing.
Kit includes; masonry chimney plate, and masonry
box.
Horizontal flue
box (R2449)
Horizontal
wall terminal
(R3650)
400 mm