Specification summary
Input
= 9-25 MJ/h
Output
= 1.6-5 kW*
Efficiency
= 73%
Energy star
= 2.8 stars*
Heating area
= 50-77 m
2
**
Gas type
= NG or ULPG
* Will vary according to gas type and flue
configuration
** Will vary depending on geographical
location in NZ
Suitability
Suitable for masonry installations
and installations into a mock
(false) chimney. Ideally suited to
living rooms and open plan areas.
Installation considerations
The Compact 2 draws air for
combustion from the room.
Adequate ventilation must be
calculated and provided by the
gasfitter as per AS/NZS 5601.1.
Burn media
Ceramic log set comes as
standard.
Convection fan
Convection fan tangential
2-speed. Heat is distributed from
the top of the appliance.
Data plate
Inside appliance on the front right
hand side panel.
Gas connection
½ “ BSPF male flare, enters from
the rear of the appliance.
Ignition
Continuous spark electronic
ignition.
Noise level
: 49 dB(A)
Operation
Push button to light pilot and
burners.
Flue - masonry
Rinnai recommends the use of a
Rinnai flexiliner flue (flexi Ø
100 mm).
Flue - mock chimney
Natural draft flue. Inner 100 mm,
outer 150 mm. Appliance must be
installed with a Rinnai flue system.
Power consumption and
electrical supply
High
= 20 W
Standby
= 0 W
Comes with a 1.5 m power cord
and 3-pin plug. The electrical
connection can exit the appliance
from the lower left or right hand
side, or from the rear of the
heater.
Safety devices
Flame failure thermocouple,
overheat switch (bi-metal strip),
fan delay, and power failure
protection.
Weight