20
|
Compact 2 Installation Guide: 11817-D 04-15
Flame pattern
It may take approximately two hours of operation for the logs to achieve their
full flame pattern and glow. During the initial burning in period, some smoke and
smell may be experienced. The appliance should run on the high setting in a well
ventilated room until these dissipate. It is important to check the flame pattern
during this time.
Abnormal flame pattern
Abnormal flame performance
and/or pattern can indicate a
problem with the fire, such as
blocked gas injectors, or log set
(burn media) has shifted from
when the fire was first installed.
There are some warning signs
that could indicate a problem.
-
Unusual smell from the
appliance
-
Continued difficulty or delay
in establishing a flame
-
Flame appears very short or
very long
-
Flame only burns part way
across the burner
-
Severe soot building up on
the inside of the glass
Important
It is the responsibility of the
installer to check that under
normal conditions of the
appliance, all flue gases are
exhausted to the outside
atmosphere, and that there is
no spillage of combustion gases
into the room.
If the appliance cannot be made
to perform correctly please
contact Rinnai.
Normal flame pattern
Abnormal flame pattern