background image

Rinnai 

RDV 600_700ER OM

WARNING

MODIFICATIONS.

DO NOT MODIFY THIS APPLIANCE

.

Modifying  from  original  specifications  may  create  a  dangerous  situation  and  will  void  your 

warranty. Failure to comply with these instructions could result in a fire or explosion, which could 

cause serious injury, death or property damage.

DO NOT 

modify the electrical wiring of this appliance.

If the power cord is damaged or deteriorated it 

MUST

 be replaced by an authorised person. 

Failure to do so may result in electric shock, fire, serious injury or product failure.
Improper installation, adjustments, service or maintenance can cause serious injury, death or 

property damage. Such work 

MUST ONLY

 be performed by an authorised person.

WARNING

GENERAL SAFETY WARNINGS

This appliance is 

HEAVY

, during installation the use of a mechanical lifting aid is recommended, 

noting that improper lifting may result in serious injury.

WARNING

: This heater 

MUST

 

NOT

 be used if any of the glass panels are damaged.

Flue terminal 

MUST

 always vent directly to outdoors. 

DO NOT

 extend the flue vertically or 

horizontally  in  ways  other  than  prescribed  in  this  appliance  manufacturer’s  installation 

instructions. 

ONLY

 the flue components specified by Rinnai 

MUST 

be used. 

When considering installation ensure minimum 

clearances as follows are adhered to, refer Fig. 1.

Heat radiating from the front of this heater 

may  over  time  affect  the  appearance  of  some 

materials used for flooring such as carpet, vinyl, 

cork or timber. This effect may be amplified if the 

air in the room contains cooking vapours, candle 

vapours and cigarette smoke, etc. To avoid this 

possibility,  it  is  recommended  that  a  mat  or 

similar protective sheet be placed in front of the 

appliance, extending at least 750 mm in front of 

the dress guard. Refer to the installation manual 

for mantle clearances, additional installation 

information and warnings.
This appliance 

MUST

 

NOT

 be installed where 

curtains  or  other  combustible  materials  could 

come into contact with it. In some cases curtains 

may need restraining.
This appliance is 

NOT

  intended  for  use  by 

persons  (including  children)  with  reduced  physical,  sensory  or  mental  capabilities  or  lack  of 

experience and knowledge, unless they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety.

The appliance is 

NOT

 intended for use by young children or infirm persons without supervision. 

Young children and the infirm 

SHOULD

 be supervised at all times when in the vicinity of this 

heater while it is in operation.
The heater 

MUST

 

NOT

 be located immediately below a power socket outlet.

A dedicated 230 V earthed 10 Amp power point must be used with this appliance.
Refer to local gas authority for confirmation of the gas type if you are in doubt.
Suitable 

ONLY

 for indoor installation.

DO NOT

 operate this appliance before leak checking hoses and gas cylinder connection.

This heater 

MUST

 

NOT

 be used if either of the glass panels are damaged.

NOT

 to be connected to an LP gas cylinder located indoors.

Please keep this instruction booklet in a safe place for future reference. All dimensions referred 

to in these instructions are in millimetres, unless otherwise specified. 

750mm

1000m

m

150mm*

150mm*

**400m

m

*150mm is the minimum clearance from 

edge of glass to combustibles.

**400mm is the minimum top clearance from 

edge of glass to underside of mantel shelf.

WARNINGS & IMPORTANT INFORMATION

Summary of Contents for 650

Page 1: ...Gas Fireplace Operation Manual Models Rinnai 650 Gas Fire RDV600ER Rinnai 750 Gas Fire RDV700ER ...

Page 2: ...and replaces all previous issues of the combined Operation Installation Manuals Part Number 12891 For details on how to install this appliance refer the Installation Manual Part Number 12903 This appliance must be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3000 AS NZS 3500 AS NZS 5601 Local Regulations and Municipal Building Codes including local OH S requ...

Page 3: ...Turn OFF Your Heater 9 Interruption to Electricity or Gas Supply During Operation 9 Restart Procedure After Interruption to Electricity Supply 9 Full Control and Partial Control 9 Remote Control Operation 10 Remote Control Activation 10 Button Functions Display Operation 10 Lost Misplaced Or Broken Remote Control 10 Battery Safety 11 Changing the Batteries 11 Care Maintenance 12 Error Codes 12 Cle...

Page 4: ...is appliance and ask for your Compliance Certificate For further information contact the Victorian Building Authority on 1300 815 127 WARNING DRESS GUARD WARNINGS The guard is fitted to this appliance to reduce the risk of fire or injury from burns and no part of it should be permanently removed For protection of young children or the infirm a secondary guard is required The wire mesh dress guard ...

Page 5: ...possibility it is recommended that a mat or similar protective sheet be placed in front of the appliance extending at least 750 mm in front of the dress guard Refer to the installation manual for mantle clearances additional installation information and warnings This appliance MUST NOT be installed where curtains or other combustible materials could come into contact with it In some cases curtains...

Page 6: ...is affect may be amplified if the air in the room contains cooking vapours or cigarette smoke To avoid this possibility it is recommended that a mat be placed in front of the appliance extending at least 750 mm in front of the heater When the heater is operated for the first time or after long periods of non use a slight odour may be emitted this is normal However if odours persist switch OFF the ...

Page 7: ...he heater to be manually restarted automatic re start will not occur Refer to the CARE AND MAINTENANCE pages 12 through 15 for further information Over heat Thermal Fuse In the unlikely event of the Over Heat Thermistor failing or some other fault occurring the Over Heat Thermal fuse will operate completely shutting the appliance down This device is a one hit only function a service call will be r...

Page 8: ... Flashes during the pilot ignition and glows solid when pilot is established going out once heating operation commences Flashes to acknowledge remote control inputs 7 Viewing window for error code display Located behind the fascia See ERROR CODES on page 12 8 Remote IR Control c Standby ON button See Remote Control Operation on page 10 d Flame Up Down buttons See Remote Control Operation on page 1...

Page 9: ...he OFF state the Red Power Indicator will be extinguished INTERRUPTION TO ELECTRICITY OR GAS SUPPLY DURING OPERATION Interruption to the power or gas supply will turn your heater OFF upon resumption of the services the appliance will need to be restarted This is a safety feature designed to ensure that un attended starts do not occur after power or gas interruptions RESTART PROCEDURE AFTER INTERRU...

Page 10: ...Flame Level 1 2 3 4 5 Fan Speed Low Low High High High NOTE On initial start up the appliance default flame height setting is 5 High The flame height may only be adjusted after at least 30 seconds of operation The remote control temperature sensor J located on the base of the controller reads the temperature of where the remote control is currently located The remote controls digital display I sho...

Page 11: ...screws M 6 With the batteries secured re attach the rear cover by carefully clipping it back into place noting that the end with the notch in it is at the bottom Noting that 0X OK will briefly be shown on the digital display to confirm that the batteries have been successfully replaced IMPORTANT Remember to dispose of used button batteries immediately and safely Dispose of used button batteries im...

Page 12: ...e Reset the heater press the Standby ON button on the control panel remote control or app twice to turn the fire back on 11 Ignition failure Check that the gas supply is turned on Switch the heater to STANDBY and then ON again If the error persists a service call will be required 12 Incomplete combustion As above 14 Inlet Blockage Overheat Clean inlet if the error persists a service call will be r...

Page 13: ...ntraction of the internal components and is normal As a safety precaution the heater will not ignite if the Standby ON button is pressed straight after the heater has been turned off It will take approximately 20 seconds for the unit to reset and switch back on again TROUBLE SHOOTING General Operation Characteristics NOTE Before asking for a service call please check the following table as these c...

Page 14: ... fan automatically comes on after 4 minutes i e once heat switch is activated Normal operation Allow heater to warm up Heat switch not activated Allow heater to run on high for 4 minutes Possible fan fault Call Rinnai Controller display blank Replace batteries Control panel operation Refer to page 10 for solution Controller not synchronised Refer to page 10 for solution Only applicable when remote...

Page 15: ...ppliance Continued difficulty or delay in establishing a flame NOTE Be advised that appliances incorporating a live fuel effect and designed to operate with luminous flames may exhibit slight carbon deposition This is normal operation CR2450 BUTTON BATTERIES CAUTION KEEP BATTERIES OUT OF REACH OF CHILDREN Swallowing button batteries may lead to serious injury in as little as 2 hours or death due t...

Page 16: ...upplied with this appliance The appliance is not intended for use by young children or infirm persons without supervision Young children and the infirm SHOULD be supervised at all times when in the vicinity of this heater while it is in operation Ensure the Customer understands that No part of this appliance should be permanently removed Young children and the infirm should be supervised at all ti...

Page 17: ...g that this information is available here will be helpful in the event that a service enquiry is required Installation Details Installation Company Name Address Telephone Mobile Phone Email Certificate of Compliance Certification No Authorised Persons Licence No Installers Name Installers Signature Installation Date Model Number Serial Number Installation Address This information will need to be c...

Page 18: ...Rinnai 18 RDV 600_700ER OM NOTES ...

Page 19: ...Rinnai 19 RDV 600_700ER OM NOTES ...

Page 20: ...tion visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced every 2 years With our policy of continuous improvement we reserve the righ...