8
Parameter
Number
Description
Number
of
Bytes
Default
Min
Max
Format
1
Heartbeats:
This parameter is the number min-
utes between heartbeats. Heart-
beats are automatic battery reports
on a timer after the last event.
1
70 (0x46)
1 (0x01)
70 (0x46)
0x01
Unsigned
2
Number of application level retries
attempted for messages either not
ACKed or messages encapsulated
via supervision get that did not
receive a report.
1
1 (0x01)
0 (0x00)
5 (0x05)
0x01
Unsigned
3
Application Level Retry Base Wait
Time Period: The number base
seconds used in the calculation for
sleeping between retry messages.
1
5 (0x05)
1 (0x01)
60 (0x3C)
0x01
Unsigned
4
This parameter allows a user, via
software, to configure the various
LED indications on the device.
0 == Don’t show green
1 == Show green after Supervision
Report Intrusion (Fault)
2 == Show green after Supervision
Report both Intrusion and Intrusion
clear
1
1 (0x01)
0 (0x00)
2 (0x01)
enum
5
The number of milliseconds
waiting for a Supervisory Report
response to a Supervisory Get
encapsulated command from the
sensor before attempting a retry.
2
1500
(0x5DC)
500 (0x1F4) 5000
(0x1388)
0x01
Unsigned
6
Occupancy Clear Delay (seconds)
2
0x00
0x00
0xFF
0x01
Unsigned
7
Intrusion Clear Delay (seconds)
1
0x05
0x00
0xFF
0x01
Unsigned
8
Standard Clear Delay (seconds)
1
0x0A
0x00
0xFF
0x01
Unsigned
9
Motion Detection Mode
1
0x03
0x00
0x04
0x01
Unsigned
10
Any motion Threshold
1
0x80
0x00
0xFF
0x01
Unsigned
11
Lighting Enabled
1
0x00
0x00
0x01
0x01
Unsigned
12
Lighting Delay
1
0x02
0x00
0x3C
0x01
Unsigned
Configuration Command Class
The sensor has the following supported configuration parameters.