Ring Alarm Motion Detector – Inclusion

Adding Ring Alarm Motion Detector to a Z-Wave Network 

 

Ring Alarm Motion Detector can be added via SmartStart or Classic inclusion mode.

Note

When prompted for the QR Code or PIN, you may find them on the device, on the box, or on a card 
inside the box. Keep the device nearby. You’ll be prompted to pull the battery tab to power on the 
device and enter setup mode.

SmartStart Inclusion Steps:

1. Initiate the add flow for Security Devices in the Ring mobile application – Follow the guided add flow  
  instructions provided in the Ring mobile application.

2. When prompted by the mobile application, scan the QR code found on the package of the  
  Motion Detector. The QR code can also be found on the device itself.

3. Pull the pull-tab or insert batteries, and the device will go into SmartStart inclusion mode. While in  
  this mode, Motion Detector can be added to a Z-Wave controller that supports SmartStart. When in  
  SmartStart inclusion mode, SmartStart can be restarted by tapping the button on the front of  
  the device.

Classic Inclusion Steps: 

Classic Inclusion should be used if the controller does not support SmartStart.

 

1. Initiate add flow for Security Devices in the Ring mobile application – Follow the guided add flow  
  instructions provided in the Ring mobile application.

2. Select add manually and enter the 5-digit DSK PIN found on the package of the Ring Alarm Motion  
  Detector or the 5-digit DSK PIN found under the QR code on the device.

3. After powering on the device, press and hold the button on the front of the device for ~3 seconds.  
  Release the button and the device will enter Classic inclusion mode which implements both classic  
  inclusion with a Node Information Frame, and Network Wide Inclusion. During Classic Inclusion  
  mode, the green LED will blink three times followed by a brief pause, repeatedly. When Classic   
  inclusion times-out, the device will blink alternating red and green a few times.

LED Behabior for Inclusion

Blink Pattern

SmartStart Started

Green LED three times, repeated after a brief pause

Classic Inclusion Started

Green LED three times, repeated after a brief pause

Classic Inclusion Timed-Out

Alternate red and green a few times

Inclusion Successful (Authenticated S2)

Green LED on solid

Inclusion Not Successful (Self-Destruct)

Red LED on solid

Summary of Contents for Motion Detector 2nd Generation Z-Wave

Page 1: ...1 Motion Detector 2nd Generation Z Wave Technical Manual ...

Page 2: ...or features and functions within the Ring app Notes 1 This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network 2 SmartStart enabled products can be added into a Z Wave network by scanning the Z Wave QR Code present on t...

Page 3: ...ouble sided tape peel the backing and attach the Motion Detector to the mounting location Note Leave in of space free on the top side to ensure you can slide open the case when it s time to change the batteries This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All mains operated nodes within the network will act as repeaters regardless ...

Page 4: ...4 ...

Page 5: ...ic Inclusion Steps Classic Inclusion should be used if the controller does not support SmartStart 1 Initiate add flow for Security Devices in the Ring mobile application Follow the guided add flow instructions provided in the Ring mobile application 2 Select add manually and enter the 5 digit DSK PIN found on the package of the Ring Alarm Motion Detector or the 5 digit DSK PIN found under the QR c...

Page 6: ...ion Detector Factory Reset Factory Default Instructions 1 To restore Ring Alarm Motion Detector to factory default settings locate the pinhole reset button on the device This is found inside the battery compartment on the back of the device after removing the back bracket 2 Using a paperclip or similar object insert it into the pinhole press and hold the button down for 10 seconds 3 The device wil...

Page 7: ...annel Association 3 Highest granted Powerlevel 1 Highest granted Security 2 1 none Supervision 1 none Transport Service 2 none Version 3 Highest granted Z Wave Plus Info 2 none Notification 8 Highest granted Wake Up 2 Highest granted Configuration 4 Highest granted Battery 2 Highest granted Association Command Class Group Identifier Max Nodes Description 1 Lifeline 0x05 1 Notification Report a See...

Page 8: ...ications on the device 0 Don t show green 1 Show green after Supervision Report Intrusion Fault 2 Show green after Supervision Report both Intrusion and Intrusion clear 1 1 0x01 0 0x00 2 0x01 enum 5 The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor before attempting a retry 2 1500 0x5DC 500 0x1F4 5000 0x1388 0x01 Unsigned...

Page 9: ...ng Value for Soft Fault 1 Lifeline Software Fault SDK Notification Report Type System 0x09 State Value 0x04 System Software Failure State Parameter Value 0xA9 SDK Value for Soft Fault 1 Lifeline Pin Reset soft reset Notification Report Type System 0x09 State Value 0x04 System Software Failure State Parameter Value 0xAB 1 Lifeline Software Reset Not triggered by failure Notification Report Type Sys...

Page 10: ...allation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Page 11: ... could void the user s authority to operate the equipment AVERTISSEMENT Tout changement ou modification à cet appareil qui n a pas fait l objet d une autorisation expresse par la partie responsable de sa conformité pourrait annuler le droit pour l utilisateur d opérer l équipement CAUTION To reduce the risk of electrical shock DO NOT open the unit There are no user serviceable parts inside the uni...