4 How to Use
4-8. Display/setting mode
- 27 -
RX-8000
<ID Display/Selection "ID SELECT">
Display and select an ID that has been registered in advance.
(1) Press the PEAK switch and select the ID display/selection from the display/setting mode menu.
The following screens are displayed in turn on the gas detector.
(2) Press the ENTER switch to set or select an ID.
NOTE
If you do not want to set or select an ID, press the ESC switch to return to the display/setting mode
menu.
On the gas detector, either of the IDs from ST-ID000 to ST-ID127 has been registered, unless
otherwise specified.
The data logger management program (option) is required to register or change an ID. Please contact
RIKEN KEIKI.
(3) Press either the
▲
or
▼
switch to select an ID.
Every time the
▲
or
▼
switch is pressed, the ID number increases or decreases (000-127).
Display example
(4) Press the ENTER switch.
(5) When END is displayed, the setting is completed.
The display/setting mode menu is displayed again.
(6) After completion, press the PEAK switch several times until it returns to the detection mode.