3 Product Components
3-1. Main unit and standard accessories
- 11 -
RX-8000
NOTE
There are the following two combinations of battery units. The
following information is printed on the battery unit for the sake of
identification to prevent a mistake in combinations.
Lithium ion battery unit : BUL-8000(R)(TC20784)
BUL-8000(R1)(TC21112)
Dry battery unit : BUD-8000(R)(TC20783)
Additionally, a nameplate indicating a compatible model is affixed
on the top of the battery unit.
Check this information and use a correct
combination.
DANGER
The specifications of the gas detector are as follows:
Pump circuit
: Allowable voltage of 4.95 V, allowable current of 1.12 A, and
allowable power of 1138 mW
Toxic gas sensor circuit : Allowable voltage of 4.95 V, allowable current of 0.834 A, and
allowable power of 853 mW
Buzzer circuit
: Allowable voltage of 4.95 V, allowable current of 0.431 A, and
allowable power of 441 mW
Main circuit
: Allowable voltage of 4.95 V, allowable current of 0.717 A, and
allowable power of 733 mW
Backup circuit
: 3.0 VDC, 10 µA
Ambient temperature
:-20 degree C to +50 degree C
< About explosion-proof of the battery unit >
The main unit that can be connected is RX-8000(TC20782) only.
The use with unspecified main units deviates from the range of explosion-proof certification.
The specifications of the BUD-8000(R) are as follows:
Pump circuit
: Maximum voltage of 4.95 V, maximum current of 1.12 A, and
maximum power of 1138 mW
Infrared detection circuit : Maximum voltage of 4.95 V, maximum current of 0.834 A, and
maximum power of 853 mW
Buzzer circuit
: Maximum voltage of 4.95 V, maximum current of 0.431 A, and
maximum power of 441 mW
Main circuit
: Maximum voltage of 4.95 V, maximum current of 0.717 A, and
maximum power of 733 mW
Power supply
: 4.5 VDC, 150 mA (LR6 3 pcs)
Ambient temperature
:-20 degree C to +50 degree C
The specifications of the BUL-8000(R), BUL-8000(R1)(TC21112) are as follows:
Pump circuit
: Maximum voltage of 4.25 V, maximum current of 1.12 A, and
maximum power of 901 mW
Infrared detection circuit : Maximum voltage of 4.25 V, maximum current of 0.768 A, and
maximum power of 618 mW
Buzzer circuit:
Maximum voltage of 4.25 V, maximum current of 0.410 A, and
maximum power of 330 mW
Main circuit
: Maximum voltage of 4.25 V, maximum current of 0.653 A, and
maximum power of 526 mW
Battery charging contact : Allowable current of 250 VAC
Ambient temperature
:-20 degree C to +50 degree C
Do not attach and remove the battery unit or batteries in the dry battery unit in a hazardous
location.
Use specified AA alkaline batteries (LR6 TOSHIBA) for the dry battery unit.
Printing for