2 Product Components
2-4. Names and functions of display
18 / 87
2-4. Names and functions of display
MODE/ESC key
Switches MEASURING MODE to other mode.
Used to stop processing.
POWER lamp (green)
Lights up at power-on.
EV1 lamp (orange)
Lights up in conjunction with Contact Output 1.
EV2 lamp (red)
Lights up in conjunction with Contact Output 2.
EV3 lamp (green)
Lights up in conjunction with Contact Output 3.
▲
key
Moves the cursor or increases the setting value.
DISP/SET key
Switches the display content in MEASURING MODE.
Confirms processing etc.
LCD display
Displays measurement values, operation statuses, or other
information.
IrDA communication port
The IrDA communication port for maintenance. Reads event log or
daily log information recorded on the product.
▼
key
Moves the cursor or decreases the setting value.
Use the attached magnet control key to operate all the switches
described in the above table. Holding the magnet control key
over the switch marks for a few seconds will start the switches.
The description of "press the XXX switch" in this operating manual
means holding the magnet control key over the marks
and
▼▲
.
Control key (magnet)
Ⅱ2G Ex dbⅡB+H2 T4 Gb