31
EN
30
Clean flue gas collecting channel
The flue gas channel should be cleaned twice a year or after approximately
700kg of pellets. The flue gas duct is located in the lower region of the
combustion chamber.
Open the firebox door.
Remove the lower front panel by simply lifting.
Remove the cover plate by opening the hexagon screws.
Suck out the combustion residues from the flue gas collection channel.
Install the removed parts in reverse order.
Note
If the seals of the cleaning cover are not properly sealed, it is possible that
the heater gets “wrong air”, causing incomplete combustion in the grate and
then an accumulation of pellets
Clean flue gas fan housing
The flue gas fan and the flue pipe connection should be cleaned at least 2 times
a year, or after about 700 kg of pellets.
To inspect and clean the flue gas fan, the back wall has to be removed.
The four screws that secure the flue gas fan motor have to be opened and the
motor is carefully to pull out of the case.
Remove with a vacuum cleaner the ash from the fan and flue gas pipes. When
closing again definitely pay attention to leaks.
For cleaning the flue pipe connection, pull the flue pipe from the flue gas fan and
suck out the blower housing.
Cleaning the flame temperature sensor
Remove the dust deposits from the sensor at regular intervals. Use a clean
cleaning cloth or newspaper.
Combustion air - intake
If necessary, please also clean the air intake with a hoover.
Note
Only when the stove is cold! The stove must not be in operation.
Cleaning the pellet container
Do not refill the completely empty container immediately; remove the residues
(dust, chippings etc.) from the empty container. The unit must be disconnected
from the mains!
Cleaning the door glass
The viewing window becomes coated in the case of solid fuels, particularly with
the very fine ash of wood pellets, light or dark depending on the pellet quality
(especially with low output). The glass can be cleaned best with a moist cloth.
Stubborn dirt can be removed with a special cleaner available from your stove
dealer.
Bearings
all built in bearings ( Pellet screw or turning Grid ) should be checked and
cleaned according to the condition or replaced min. once per Year.
Checking door seal
The condition of the seals at doors and glass should be checked at least 1 x per
year. Repair or replace seals depending on condition.
Checking chimneay connection
Inspect and clean connection. Accumulated fly ash may impair the performance
of the stove and pose a safety risk.