14
7. INTERNAL CONTROLS
The stove has a modern programmable microprocessor control. The individual
unit functions can be preset by the user via the internal controls located in the
right casing (keyboard with operating display).
Basics
Note
Manipulation of hardware components may only be performed by trained
specialist dealers and service. Incorrect handling of these parts leads to
loss of warranty and guarantee claims!
Note
The unit may only be put into operation when assembled completely!
Operation
All settings and functions can be controlled via this unit.
The display is illuminated when touched. After some seconds the display lighting
turns off again.
EASY MODE - simple heating operation
Your stove is in simple heating mode EASY OFF when delivered in order to ease
your start in the world of RIKA pellet stoves. The heat output of the stove can
only be increased or reduced in 5 % increments in this mode. As soon as the
stove is connected to the socket, the standard display EASY OFF appears.
The message „CHECK“ appears in the display as soon as your pellet stove is
connected to the power supply (even after a power failure). The display buttons
are disabled for approx. 10 seconds as the stove conducts an initialisation of
all components. When „CHECK“ disappears from the display the stove can be
started up.
"CHECK" appears in the display whenever
the stove ist re-supplied with power.
CHECK
EASY OFF - inactive state
key
display
description
EASY OFF
Standard display for stove switched off in
simple heating mode.The output can also be
regulated between 30% and 100% with the
stove switched off (EASY 30 – EASY 100).
EASY 45
Pressing increases output by 5%
EASY 35
Pressing decreases output by 5%
Start - scavenge - tip - ignition
The pellet stove is started in the scavenging phase by pressing the
button.
The scavenging phase lasts approx. 50 seconds and is used to eliminate any
adverse draft conditions in a cold flue. The grate tips automatically during the
scavenging process and any ash leftover from the previous combustion phase
falls into the ash tray.
Depending on the fill level of the screw conveyor the ignition process can take
approx. 5 to 30 minutes until the first flame is visible.
If the first ignition attempt is unsuccessful, further ignition attempts will be
initiated automatically. This may occur if the screw conveyor is not completely
full during the ignition process (e.g. first start after refilling empty container).
Note
In the event of a false start remove any unburnt pellets and ash from the
combustion cavity. Never replace unburned pellets from the fire pot in the
supply container.
FIRE HAZARD DUE TO RESIDUAL EMBERS
Summary of Contents for Memo
Page 1: ...Operating Manual MEMO ...
Page 4: ...Spare part overview exploded diagram ...
Page 5: ... 5 EN 4 ...