Channel
OVP/OCP Available Range
OVP/OCP
Default Value
DP932E
CH1 (30 V/3 A)
1 mV to 33 V/1 mA to 3.3 A
33 V/3.3 A
CH2 (30 V/3 A)
1 mV to 33 V/1 mA to 3.3 A
33 V/3.3 A
CH3 (6 V/3 A)
1 mV to 6.6 V/1 mA to 3.3 A
6.6 V/3.3 A
4.8.1
:OUTPut:CVCC?
Syntax
:OUTPut:CVCC?
[<
source>]
Description
Queries the output mode (CV, CC, or UR) for the specified channel.
Parameter
Name
Type
Range
Default
<source>
Discrete
{CH1|CH2|CH3}
-
Remarks
•
This series power supply has three output modes: constant voltage (CV),
constant current (CC), and unregulated (UR). In CV mode, the output voltage
equals to the voltage setting value, and the output current is determined by the
load; whereas in CC mode, the output current equals to the current setting value,
and the output voltage is determined by the load. UR mode is the unregulated
mode between CV and CC mode.
•
If <source> is omitted, the command queries the output mode of the current
channel.
Return Format
The query returns CV, CC, or UR.
Examples
:OUTPut:CVCC? CH1 /*Queries the current output mode of CH1. The
query returns CV.*/
4.8.2