background image

6 Informativity

The Detector ensures transmission and indication of the following 

messages:

- normal state message;
- alarm message;
- tamper message;
- main power-supply low-battery message;
- backup power-supply low-battery message;
- «Binding» mode indication;
- «Identification» mode indication;
- communication quality indication.

7 Detection Pattern

1 Introduction

Wireless passive infrared detector «Foton-19RK» (hereinafter, the 

Detector) is intended for detecting intrusion into a closed protected 
space and generating an alarm message.

The Detector highlights:
- generates status messages via a two-way wireless channel 

within the 433.05

 — 

434.79 MHz frequency range according to  

«Rielta-Contact-R» wireless two-way data exchange protocol;

- is intended to operate as a component of a system that is operated 

by any control panel (hereinafter, CP) supporting «Rielta-Contact-R» 
wireless two-way data exchange protocol; 

- ensures case tamper protection;
- is resistant to the ambient light impact and radio interference;
- does not generate false alarms caused by the movement of:

a) short-haired pets weighting up to 20 kg (with temperature  

contrast 8 °С);

b) long-haired pets weighing up to 40 kg (with temperature 

contrast 6 °С);

- the Detector is installed directly on a wall or in a corner of a room.

2 Features of the Detector

- Dual-element pyrodetector.
- Distortions preventation in the detection zone by means of  

spherical lens.

- Pet immunity.
- Protection against ingress of insects to the pyroelectric.
- Pet immunity adjustment (10, 20 or 40 kg pet weight).
- Automatic switching to a backup operating frequency in case of 

an imperfect interference situation on the main one.

- Built-in main and backup power supply.

3 Specifications

Table 1 

Features

Value

Detection zone size

10 x 10 m

Detection zones 

8 long-range zones, 4 short-range zones

Maximum detection range

10 m

Pet immunity

Jumper «10kg» installed — 10 kg

Jumper «10kg» removed — 20 kg (contrast 

8 °С) or 40 kg (contrast 6 °С)

Operating temperature 

from minus 20 °С to +50 °С

Dimensions, maximum

105 х 75 х 56 mm

Weight, maximum

0.1 kg

Battery life (under normal 

climatic conditions and with a 

radio exchange period equal 

to at least 30 sec)

up to 5 years

IP rating

IP41

The Detector is powered by a main lithium power-supply battery 

СR123A type and СR2032 backup one.

4 Scope of Delivery

Each Detector unit package contains the items listed in Table 2.
Table 2

Name

QNT 

Wireless passive infrared detector «Foton-19RK»
Screw 3-3х30.016 
Wall plug NAT 5х25 SORMAT
Screw 2,9х6,5 DIN7981F
СR123A lithium power supply battery
СR2032 lithium power supply battery
Wireless passive infrared detector «Foton-19RK». Installation 

Guide

1 pc.

2 pcs.
2 pcs.

1 pc.
1 pc.
1 pc.

1 copy

5 Field of Application

The Detector can be installed in apartments, as well as in shops, 

offices, museums and industrial facilities. The Detector may be 
installed in premises, that are inhabited by pets weighing up to 
40 kg (20 kg).

WIRELESS  PASSIVE  INFRARED           

DETECTOR 

WITH PET IMMUNITY

«

FOTON-19RK

»

Installation Guide

Top View

Side View

Figure 1

8 LED Indication

Table 3

Detector State

LED Indication

«Binding»

LED status

Operation mode

«Alarm»*

LED indicator blinks 

green

«Identification»

LED indicator lights red 

for at least 0.5 sec

if indication is enabled

«Connection quality»

LED indicator blinks 

red and green 

alternately at 1 Hz 

frequency

by a command from 

the CP

Binding procedure 

completed

See «Communication Quality Appraising»

Binding procedure 

completed

LED indicator lights red 

for 2 sec

*) — Alarm indication is deactivated 15 min after the Detector cover is closed 

and activated after it has been opened or by a command from the CP.

9 Binding with the CP

The Binding procedure is intended for logging of the Detector in the 

CP and transmission of service information to it.

9.1 Prepare the CP for the Detector logging in accordance to the 

CP manual.

9.2 Install the СR2032 backup power-supply battery into the holder 

located on the reverse side of the Detector printed circuit board (PCB).

9.3 Install the PCB into the Detector case, and then install the 

СR123А main power-supply battery.

9.4 Blinking of the LED indicator green displays the Detector 

readiness for the binding procedure. In case the LED indicator does 
not blink, close the «Reset» contacts for a short period.

9.5 After a successful binding with the CP, the LED indicator lights 

red for 2 sec.

9.6 The «Binding» procedure is limited to 100 sec. After it expires, 

the Detector switches to the sleep mode. To resume the «Binding» 
mode, the «Reset» contacts should be temporary closed.

10 Choosing an Installation Place for the Detector

The  Detector  must  be  located  in  the  radio-coverage  zone  of  it’s 

CP. Therefore, it is advisable to appraise quality of communication 
beforehand. The procedure of communication quality appraising is 
described in the chapter «Communication Quality Appraising».

When choosing the Detector installation place, it is advisable 

to take note of the fact that the detection zone may be limited by  
non-transparent objects (curtains, houseplants, cabinets, bookcases, 
etc.), as well as glass and mesh partitions. There must be no windows, 
air conditioners, space heaters or heating radiators in the Detector 
visibility zone. The presence of furniture items on which an animal may 
climb in the detection zone may cause a false alarm.

Recommended installation height 

 2.3 m from the floor.

The Detector should be installed at least 0.5 m distance from 

electric cables.

10 m

10 m

2.3 m

0

0

90

о

Reviews: