14 Detector Behavior
14.1 The Detector is powered on and off by installation and removal
of the main power-supply battery.
14.2 After loss of communication with the CP, the Detector will
continue to search for the CP. In case the CP is disabled for a long
time, it is recommended to power off the Detector (see Cl. 14.1).
14.3 It must be taken into account, that in case of the Detector
operation 5 °C to minus 20 °C temperature range, the battery
life may be less than 5 years.
ATTENTION!
The Detector must be checked at least annually in
order to test it’s performance.
15 Storage and Transportation
15.1 The Detectors in their original packing may be shipped by any
transport means in covered vehicles (in railway, cars, trucks, sealed
heated compartments of aircraft, ship cargo holds, etc). The Detector
is resistant to:
а) transport jolting with the acceleration 30 m/sec
2
with impact
frequency from 10 to 120 impacts/sec or 15000 impacts with the same
acceleration;
b) the ambient temperature minus 50 … +50 °С;
c) relative air humidity (95 ± 3) % at the ambient tempe35 °С.
15.2 After transportation under the conditions different to exploitation
conditions the Detector shall be ready to operate after a maximum
of six hours.
15.3 The storage room shall be free from current-conducting
dust, acid vapors, alkali and gases that cause corrosion and destroy
insulation.
16 Manufacturer’s Guarantees
16.1 The Manufacturer guarantees conformity of the Detector to
its Technical Specifications if conditions of transportation, storage,
assembling and operation are observed. The guaranteed storage
period is 63 months since the date of manufacturing the Detector.
16.2 The guaranteed period of operation is 60 months since the date
of commissioning within the storage period guaranteed.
16.3 The Detectors that are found to non-conforming to their
Technical Requirements shall be repaired by the Manufacturer,
provided that the installation and operation rules have been complied
with.
Note
— Warranty obligations are not applied to the power-supply
batteries.
17 Acceptance and Packing Certificate
Wireless passive infrared detector «Foton-19RK»,
lot No __________________________,
manufactured in accordance with current technical documentation
is classified as fit for operation and is packed by «RIELTA» JSC.
Person responsible for acceptance and packing
Representative of QCD ________________ __________________.
Date, month, year
11 Communication Quality Appraising
Before installing the Detector to it’s place of operation, it is advisable
to appraise the CP communication quality as follows.
11.1 Prepare the Detector for operation and put it on its location
place with a closed cover.
11.2 Open the Detector case, whereupon the Detector will indicate
the quality of CP communication.
Table 4
LED indication
Communication
Quality Appraisal
Recommendations
LED indicator blinks green
three times
Excellent
Install the Detector
at this place
LED indicator blinks green two
times
Good
LED indicator blinks green one
time
Communication
established
Choose another
place of installation
or use a repeater*)
LED indicator blinks red four
times
No communication
*) — «Ladoga BRSS-RK-RTR» or «Ladoga BRSS-RK-RTR» ver. 1
12 Installing the Detector
Before installing the Detector, remove it’s cover and the PCB. For
this purpose:
- remove the cover of the Detector;
- loosen the screw fastening the PCB, move it upwards and remove
it from the Detector base;
- drill the holes (Figure 2) in the base of the Detector case. They
will be used for fastening the Detector;
- choose the installation place, mark out and drill the installation
places in the wall with regard for the position of the holes on the
Detector base;
- fasten the Detector base in the chosen place;
- reinstall the PCB;
- put on the cover, screw in the retainer screw 2.9x6.5 DIN7981F
(supplied).
Note
— To exclude false alarms in the pet immunity mode, the
Detector should be installed vertically.
«RIELTA» JSC, www.rielta.ru,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],
Tel./fax. +7 (812) 233-0302, 703-1360,
Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected]
Made in Russia
Rev. 3 of 10.11.14
V.7.1
Figure 2
13 Functional Testing
In presence of the pets weighing up to 40 kg in the room, remove
the «10 kg» jumper, in presence of the pets weighting less than 10 kg
in the room, install the «10 kg» jumper.
It is advisable to remove the «10 kg» jumper in the premises with a
high interference level.
Start walking across the detection zone. After 3
— 4 steps across
the detection zone, the Detector should display the detection by the
LED indicator red blink. Wait for 10 sec and continue walking across
the detection zone. There must be no indication in absence of moving
objects in the room. If the Detector fails to detect moving objects in the
detection zone, it’s position on the swivel bracket should be changed.
Base
Holes for
fastening in a
corner
Hole for the PCB
fashening screw
Holes for installation
on a wall
Location of the