14 Detector Behavior

14.1 The Detector is powered on and off by installation and removal 

of the main power-supply battery.

14.2 After loss of communication with the CP, the Detector will 

continue to search for the CP. In case the CP is disabled for a long 
time, it is recommended to power off the Detector (see Cl. 14.1).

14.3 It must be taken into account, that in case of the Detector 

operation 5 °C to minus 20 °C temperature range, the battery 
life may be less than 5 years.

ATTENTION!

 The Detector must be checked at least annually in 

order to test it’s performance.

15 Storage and Transportation 

15.1 The Detectors in their original packing may be shipped by any 

transport means in covered vehicles (in railway, cars, trucks, sealed 
heated compartments of aircraft, ship cargo holds, etc). The Detector 
is resistant to:

а)  transport  jolting  with  the  acceleration    30  m/sec

2

 with impact 

frequency from 10 to 120 impacts/sec or 15000 impacts with the same

 

acceleration;

b) the ambient temperature minus 50 … +50 °С;

c) relative air humidity (95 ± 3) % at the ambient tempe35 °С.
15.2 After transportation under the conditions different to exploitation 

conditions the Detector shall be ready to operate after a maximum 
of six hours.

15.3 The storage room shall be free from current-conducting 

dust, acid vapors, alkali and gases that cause corrosion and destroy 
insulation.

16 Manufacturer’s Guarantees

16.1 The Manufacturer guarantees conformity of the Detector to 

its Technical Specifications if conditions of transportation, storage, 
assembling and operation are observed. The guaranteed storage 
period is 63 months since the date of manufacturing the Detector.

16.2 The guaranteed period of operation is 60 months since the date 

of commissioning within the storage period guaranteed.

16.3 The Detectors that are found to non-conforming to their 

Technical Requirements shall be repaired by the Manufacturer, 
provided that the installation and operation rules have been complied 
with.

Note 

— Warranty obligations are not applied to the power-supply 

batteries.

17 Acceptance and Packing Certificate

 

Wireless passive infrared detector «Foton-19RK»,

lot No __________________________,
manufactured in accordance with current technical documentation 

is classified as fit for operation and is packed by «RIELTA» JSC.

Person responsible for acceptance and packing

Representative of QCD ________________    __________________.
                                                                

Date, month, year

11 Communication Quality Appraising 

Before installing the Detector to it’s place of operation, it is advisable 

to appraise the CP communication quality as follows.

11.1 Prepare the Detector for operation and put it on its location 

place with a closed cover.

11.2 Open the Detector case, whereupon the Detector will indicate 

the quality of CP communication.

Table 4

LED indication

Communication 

Quality Appraisal

Recommendations

LED indicator blinks green 

three times

Excellent

Install the Detector 

at this place

LED indicator blinks green two 

times

Good

LED indicator blinks green one 

time

Communication 

established

Choose another 

place of installation 

or use a repeater*)

LED indicator blinks red four 

times

No communication

*) — «Ladoga BRSS-RK-RTR» or «Ladoga BRSS-RK-RTR» ver. 1

12 Installing the Detector

Before installing the Detector, remove it’s cover and the PCB. For 

this purpose:

- remove the cover of the Detector;
- loosen the screw fastening the PCB, move it upwards and remove 

it from the Detector base;

- drill the holes (Figure 2) in the base of the Detector case. They 

will be used for fastening the Detector;

- choose the installation place, mark out and drill the installation 

places in the wall with regard for the position of the holes on the 
Detector base;

- fasten the Detector base in the chosen place;
- reinstall the PCB;
- put on the cover, screw in the retainer screw 2.9x6.5 DIN7981F 

(supplied).

Note 

— To exclude false alarms in the pet immunity mode, the 

Detector should be installed vertically.

«RIELTA» JSC, www.rielta.ru,
Chapaeva Str. 17, Saint Petersburg, Russia, 197101, [email protected],

Tel./fax. +7 (812) 233-0302, 703-1360,

Technical support, tel. +7 (812) 233-29-53, 703-13-57, [email protected]

Made in Russia

Rev. 3 of 10.11.14

V.7.1

Figure 2

13 Functional Testing

In presence of the pets weighing up to 40 kg in the room, remove 

the «10 kg» jumper, in presence of the pets weighting less than 10 kg 
in the room, install the «10 kg» jumper.

It is advisable to remove the «10 kg» jumper in the premises with a 

high interference level.

Start walking across the detection zone. After 3

 

— 4 steps across 

the detection zone, the Detector should display the detection by the 
LED indicator red blink. Wait for 10 sec and continue walking across 
the detection zone. There must be no indication in absence of moving 
objects in the room. If the Detector fails to detect moving objects in the 

detection zone, it’s position on the swivel bracket should be changed.

Base

Holes for 

fastening in a 

corner

Hole for the PCB 

fashening screw

Holes for installation 

on a wall

Location of the 

fastening