![Riello RS 500/E LN Installation, Use And Maintenance Instructions Download Page 29](http://html1.mh-extra.com/html/riello/rs-500-e-ln/rs-500-e-ln_installation-use-and-maintenance-instructions_1459886029.webp)
20008423
27
GB
4.16 Motor connection at 208-230 or 460V only for RS 400/E LN - RS 500/E LN
WARNING
:
the motors, manufactured for 208-230/460V
IE2/Epact
voltage, have a different connection than
IE1
motors, no more star/delta but
star/double star.
Please, pay attention to the indications in case of modification of voltage, maintenance, or substitution.
4.17 Motor connection at 575V only for RS 400/E LN - RS 500/E LN
WARNING
:
the motors, manufactured for 575V
IE2/Epact
voltage, have the same control box base of the IE1 motors.
Please pay attention to the indications in case of maintenance or substitution.
4.18 Reversible direction
WARNING
:
If it is necessary to reverse the direction then reverse the two main supply phases.
For example: L1 with L2, there is not difference between
IE1
and
IE2/Epact
.
U2
V2
W2
U5
V5
W5
U1
V1
W1
U2
V2
W2
U5
V5
W5
U1
V1
W1
D3686
IE1
IE2/Epact
S8406
S8407
~ ~ ~
~ ~ ~
460V
208-230V
~
~
~
~
~
~
460V
208-230V
Fig. 30
S8382
~ ~ ~
575V
Fig. 31
S8447
L1
L2
Fig. 32