11
20095002
GB
Technical description of the burner
4.8
Test boiler
The firing rates were obtained in special test boilers, according to
EN 676 regulations.
Fig. 4 indicates the diameter and length of the test combustion
chamber.
Example
:
Output 756 kW (650 Mcal/h) - diameter 60 cm, length 2 m.
The coupling is ensured when the boiler is EC type-approved; for
boilers or ovens with combustion chambers of very different di-
mensions compared to those shown in the diagram of Fig. 4, pre-
liminary checks are recommended.
4.9
Burner equipment
The burner is supplied complete with:
Gas train flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
Gasket for gas train flange . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
Thermal insulation screen . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
Screws M10 x 35 to fix the flange . . . . . . . . . . . . . . . . . . . No. 4
Screws M12 x 35 to fix the burner flange to the boiler . . . . No. 4
Instruction manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
Spare parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
Fig. 4
Combustion
ch
amber
le
ngh
t -
m
D715