9
20095002
GB
Technical description of the burner
4.6
Maximum dimensions
The dimensions of the burner are shown in Fig. 1.
Bear in mind that inspection of the combustion head requires the
burner to be opened and the rear part drawn back on the guides.
The dimensions of the open burner are indicated by position I.
Tab. E
(1) Blast tube: short-long
4.7
Firing rate
The
maximum output
is chosen within area A of the diagram
(Fig. 2).
The
minimum output
must not be lower than the minimum limit
of the diagram.
Fig. 1
D1206
mm
A
B
C
D
E
F
(1)
G
H
I
(1)
L
M
N
O
RS 160/EV BLU
681
366
315
555
872
373-503
222
430
1442-1587
230
141
260
2”
WARNING
The firing rate (Fig. 2) was obtained considering a
room temperature of 20°C and an atmospheric
pressure of 1013 mbar (approx. 0 m above sea
level), with the combustion head adjusted as
shown at page 25.
Fig. 2
Thermal power
Combustion
ch
amber
pr
ess
u
re
-
mbar
D11264