Technical description of the burner
7
20095042
GB
Tab. C
3.3
Burner models designation
Tab. D
3.4
Packaging - weight - Approximate measurements
The burners are skid mounted. Outer dimensions of packaging are
indicated in Tab. E.
The weight of the burner complete with packaging is indicated in
Tab. E.
Tab. E
Model
RLS 200/E
RBNA Code
C9355400
C9355410
Control circuit power supply
V/Ph/Hz
120/1/60
Main power supply (+/- 10%)
V/Ph/Hz
230/3/60
460/3/60
Fan motor IE2/EPACT
rpm
HP
V
A
3500
7.5
230
17.8
3500
7.5
460
8.9
Pump motor IE2/EPACT
rpm
HP
V
A
3530
1
230
3
3530
1
460
1.5
Ignition transformer
Oil
V1 - V2
I1 - I2
120 V - 2 x 5 kV
2.7 A - 30 mA
Gas
V1 - V2
I1 - I2
120 V - 1 x 8 kV
1.6 A - 20 mA
Electrical power consumption
W
7000
7000
Electrical control circuit consumption
W max
750
Total electrical consumption
W
7750
7750
Electrical protection
NEMA 1
Model
Code
Code RBNA
Voltage
Flame safeguard
RLS 160/E
20113149
C9354400
230/3/60
Burner mounted
C9354410
460/3/60
20023415
C9354401
575/3/60
RLS 200/E
20127086
C9355400
230/3/60
Burner mounted
C9355410
460/3/60
inch
A
B
C
lbs
RLS 160/E
59
1
/
16”
33
43
/
64”
39
3
/
8”
210
RLS 200/E
59
1
/
16”
33
43
/
64”
39
3
/
8”
210