4.3 BEFORE SWITCHING ON
Be
fore switching the appliance on, please familiarize yourself with:
-
how to isolate the appliance from the gas, water, and
electrical supplies;
-
how to check and top-up – if necessary – the system water
pressure;
-
any external thermostats and their functions;
-
the appliance controls.
4.4 APPLIANCE CONTROLS
NOTICE
The appliance frost protection is active in all the boiler modes.
The control panel functions can be used to vary the temperature
of the water that circulates around your heating system and the
water that flows from your hot water taps.
The heating temperature range can be adjusted between 68°F
- 113°F (20°C - 45°C) (for low temperature) or 68°F - 180°F (20°C
- 82°C) (for high temperature) this range is configured by your
installer and the default is the high temperature range. The hot
water temperature range can be adjusted between 99°F -
140°F (37°C - 60°C).
NOTICE:
the actual delivery temperature is also conditional upon
the incoming water temperature and the actual flow-rate at the
outlet.
Refer to the section 4.12 for fault indicator and boiler status.
4.5 LIGHTING THE BOILER
1
Set the thermostat to lowest setting.
2
Turn off all electric power to the appliance.
3
This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light the burner
by hand.
4
Turn external gas shutoff valve clockwise to close valve to
the full OFF position.
5
Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP!
6
Turn gas shutoff valve counterclockwise to open valve to the
ON position.
7
Turn on all electrical power to the appliance.
8 Set thermostat to desired setting.
9
If the appliance will not operate, follow the instructions
to Turn Off Gas To the Appliance” and call your service
technician or gas supplier.
After completing all operations required to prepare
commissioning, proceed as with the instructions in sections 4.6
and 4.7 sequentially to complete lighting the boiler.
4.6 PROGRAMMING THE BOILER
− Turn the systems master power
switch
to the “ON” position.
“Start-up phase” activates to check the display function.
On the display, the following checks will happen:
- Display functionalities: all icons available and sliding the
“RIELLO” text will appear. Press the
“
MODE/OK” button
in order
to stop the display testing
RESET
MENU
RIELL
OK
MODE
- Display firmware version: e. g. FW0.1 (no actions are required)
RESET
MENU
FWX.Y
OK
MODE
- Set language (“ITA”=Italian, “ENG”=Us). Rotate one of the two
dials to choose the preferred language (“ENG” default)
- press the
“
MODE/OK” button in order to confirm. If the
“MODE/
OK” button is not pressed, the default language is left set up.
RESET
MENU
ENG
OK
MODE
RESET
MENU
ENG
OK
MODE
- After the “Start-up phase”, “WAIT COMM.” will always appear,
which means that the SC07 front control is waiting for
communication with the boiler. After which, the “Operation
phase” starts: in this phase it is possibile to perform all the
supported actions (with the exception of language selection).
The controller stays in the “Operation mode” for 20 seconds
starting from the last time a knob was rotated or a key was
pressed. After 20 seconds has expired, the controller goes into
a “Stand-by” mode, backlight OFF. If there is a knob rotation
or a button pressed the device goes back to the “Operation
mode”, backlight ON, for a period of 20 seconds.
4.7 FIRST COMMISSIONING
- Rotate the system’s master switch to the “on” position.
- Open the gas tap to allow fuel to flow.
- Adjust the room thermostat to the desired temperature (~72°F/
22°F) or, if the system is equipped with a programmable
thermostat, set the occupancy temperature to the desired
temperature. Ensure that the thermostat is “active” and set
correctly (~72°F/ 22°F)
- Then press the
“
MODE/OK” button repeatedly to select CH or
CH/DHW mode
RESET
MENU
136°F
OK
MODE