Positioning
Separate the User interface from the base.
Mark the fastening points using the base as template
Drill a hole in the wall for the passage of cable connec-
tions.
1. Fixing holes
2. Terminal blocks
3. Hole for connection passage
Connections
Make the cable for connecting the User interface with
the equipment pass through the hole on the base.
Fasten the base using suitable screws and plugs.
Connect the cable to the interface terminals referring to
chapter “Internal unit terminal block”
p. 43.
Install the User interface on the base.
A. Internal unit terminal block
B. User interface terminal block
Adjustments
Set the parameters 104 and 105 and adjust the climatic
curves (see paragraph “Climatic curves”
p. 61).
IT
Posizionamento
Separare il pannello comandi dalla base.
Tracciare i punti di fissaggio utilizzando la base come dima
Praticare un foro nella parete per il passaggio dei collega-
menti.
1. Fori di fissaggio
2. Morsettiera
3. Foro per passaggio connessioni
1,5 m
OK
1
2
3
1
Collegamento
Far passare il cavo per il collegamento del pannello co-
mandi all’apparecchio attraverso il foro presente sulla ba-
se.
Fissare la base utilizzando viti e tasselli idonei.
Collegare il cavo ai morsetti del comando rispettando fa-
cendo riferimento al capitolo “Morsettiera unità inter-
na”
p. 43.
Montare il pannello comandi sulla base.
A. Morsettiera unità interna
B. Morsettiera pannello comandi
Y
Y
G
G
C
C
W
W
Y
Y
G
G
C
C
W
W
R c
R h
W
C
G
Y
Rc
Rh
W
C
G
Y
A
B
Regolazioni
Settare i parametri 104 e 105 e regolare le curve climatiche
(vedi paragrafo “Curve climatiche”
p. 61).