35
INSTALLATION
Menu
Par.
No.
Description
Range
Default setting
INSIEME EVOe 25
B/70 LN
UM
Access
2000
2322
Zone 3 basic external temperature
It sets the external temperature at which the boiler
setpoint must be reduced, according to the value de-
fined in parameter 2321.
5...30
20
°C
I
2000
2325
Zone 3 summer/winter switching
It blocks the heating request when the external tem-
perature is greater than this setpoint.
0...35
20
°C
I
2000
2330
Parallel shift of direct Zone/Zone 1 climatic curve
-10…10
0
°C
U
2000
2331
Zone 3 mild climate temperature compensation
0...20
0
°C
I
2000
2332
Zone 3 ambient temperature nominal value
When an OpenTherm (OT) ambient thermostat is con-
nected to the zone control accessory, this parameter
is not used.
5...35
20
°C
I
2000
2334
Compensation factor of Zone 3 external temperature
0...100
50
%
I
2000
2335
Zone 3 mixing valve closing time
0...240
140
sec
I
2000
2336
Zone 3 mixing valve PID P
0...99
5
I
2000
2337
Zone 3 mixing valve PID I
0...99
10
I
2000
2338 Zone 3 valve operating time
0...255
2
I
2000
2339
Supply Extra
Only for MIX Zone
0...20
5
°C
I
2000
2340 Zone 3 circulator post-circulating time
(...)
30
sec
I
2000
2341
Zone 3 delivery overtemperature protection
0...100
55
°C
I
2000
2342
Zone 3 overtemperature control time
0…240
0
min
I
2000
2343
Zone 3 overtemperature stand-by time
0…240
2
min
I
2000
2344 Zone 3 system reset time
0…240
2
min
I
DHW settings and system configuration
2000
2047
DHW setpoint with heater
40...65
57
°C
U
2000
2036
Hysteresis for heater DHW request start
If the heater temperature goes below the DHW
setpoint minus the hysteresis value defined in this
parameter, the regulator confirms the fulfilment of
the request.
0...20
3
°C
I
2000
2037
Hysteresis for heater DHW request stop
If the heater temperature goes above the DHW
setpoint plus the hysteresis value defined in this
parameter, the regulator confirms the stop of the
request.
0...20
3
°C
I
2000
2038
Thermal unit delivery temperature increase in DHW
mode with heater
It increases the delivery temperature to the boiler by
the value set in this parameter.
0...30
15
°C
I
2000
2042
Heat request priority
0 = Time priority between domestic and heating
mode defined by Par. 2043.
1 = Heating mode priority
2 = Domestic mode priority
0...2
2
I
2000
2043
Time for which the priority is alternately assigned to
domestic and heating circuits when the Par. 2042 is
set to "0” mode (for heater only).
0...120
60
min
I
2000
2041
Primary setpoint for heater with thermostat
50...82
75
°C
I
2000
2044 Circulator post-circulating time in domestic mode.
10...900
120
sec
I
2000
2045
DHW Enable PO Input
0 = DHW always enabled
1 = DHW enable input via PO input
0...1
0
I
2000
2048 DHW setpoint with instant production
40…70
45
°C
U
2000
2049
Circulator modulation in DHW mode
The circulator modulation can vary between 50% = 5
and 100% = 10
5...10
9
10*%
I
2000
2052
DCW minimum temperature setpoint of DHW ex-
changer (it activates pump and diverting valve on
domestic circuit)
10...35
25
°C
I
2000
2053
DCW maximum temperature setpoint of DHW ex-
changer (it deactivates pump and diverting valve on
domestic circuit)
10...35
25
°C
I
2000
2056 Boiler minimum holding temperature for DHW in-
stant production
20...82
60
°C
I
2000
2061
Boiler setpoint for DHW instant production
40...82
80
°C
I
2000
2062
∆T boiler switch-off setpoint for DHW production
0...3
1
°C
I