31
INSTALLATION
2.17
List of parameters
9
The programming lines can be hidden, according to the access level (User, Installer) and to
the thermal unit configuration.
9
The parameters of Installer level must be changed only by the Technical Assistance Service
R
.
Access level:
U:
End user
I: Installer
Key:
DHW
Domestic hot water
HT
High temperature direct circuit
BT
Low temperature mixed circuit
DCW
Domestic cold water
OT
OpenTherm
SA
Ambient probe
SE
Outdoor sensor
TA
Room thermostat
Menu
Par.
No.
Description
Range
Default setting
INSIEME EVOe 25
B/70 LN
UM
Access
Main menu
0000
013
Quick adjustment of direct Zone/Zone 1 heating set-
point in 0 and 3 heating modes.
By connecting the zone control accessory, this pa-
rameter can be used to quickly change direct Zone/
Zone 1 setpoint. This parameter simultaneously mod-
ifies the value of Par. 2103.
See Par. 2103
See Par. 2103
°C
U
0000
023
Quick adjustment of Zone 2 heating setpoint in 0 and
3 heating modes.
By connecting the zone control accessory, this
parameter can be used to quickly change Zone 2
setpoint. This parameter simultaneously modifies the
value of Par. 2203.
See Par. 2203
See Par. 2203
°C
U
0000
033
Quick adjustment of Zone 3 heating setpoint in 0 and
3 heating modes.
By connecting the zone control accessory, this
parameter can be used to quickly change Zone 3
setpoint. This parameter simultaneously modifies the
value of Par. 2303.
See Par. 2303
See Par. 2303
°C
U
0000
047
Quick adjustment of DHW setpoint with heater
See Par. 2047
°C
U
0000
048
Quick adjustment of DHW setpoint with instant pro-
duction
See Par. 2048
°C
U
0000
200
Test mode
0 = Function disabled
1= Function active
0…1
0
I
0000
201
Stops the venting function
0 = No action
1 = Stop venting
0…1
0
U
0000
901
Unit of measurement for temperature
0 = °C
1 = °F
0...1
0
U
0000
902
Pressure unit of measurement
0 = BAR
1 = PSI
0...1
0
U
Info menu
1000
1101
Direct Zone/Zone 1 delivery temperature
°C
U
1000
1102
Direct Zone/Zone 1 ambient temperature
°C
U
1000
1201
Zone 2 delivery temperature
°C
U
1000
1202
Zone 2 ambient temperature
°C
U
1000
1301
Zone 3 delivery temperature
°C
U
1000
1302
Zone 3 ambient temperature
°C
U
1000
1001
CH flow temperature
°C
U
1000
1002
Domestic hot water temperature
°C
U
1000
1003
Domestic cold water temperature
°C
U
1000
1004
Outdoor temperature
°C
U
1000
1007
Return temperature
°C
U
1000
1033
System pressure
bar
U
1000
1032
Error code
U
1000
1112
Zone 1 heating setpoint
°C
U
1000
1113
Zone 2 heating setpoint
°C
U
1000
1114
Zone 3 heating setpoint
°C
U
1000
1056
Total hours of operation in heating mode
h x 10
U
Summary of Contents for INSIEME EVOe 25 B/70 LN
Page 1: ...cod 20129498 rev 2 03 2019 INSIEME EVOe 25 B 70 LN EN INSTALLATION AND MAINTENANCE MANUAL...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...