background image

16

CONDENSING GENERATORS

Wall-hung gas condensing modules

Image

Description

CONDEXA PRO

50 P 70 P 100 P

2-way valve kit: 

this valve can be installed only coupled with one 

of the “Plate heat exchanger kit” in order to satisfy also the DHW 
request.

• • •

Flow / return connection kit for 35-135 "direct" installation

piping for the "direct" connection to the secondary system
The kit is suitable for systems where no hydraulic separator is 
required.
It contains both flow/return connections for the heating circuit 
and return connection for DHW circuit.

• • •

Expansion vessel kit for 50 stand alone boiler

: 18 l expansion 

vessel with pipes (¾" M connection) and connection brackets for 
the installation inside the boiler casing.

Cover for plate heat exchanger:

 painted metal sheet that 

protects the plate heat exchanger in the "outdoor" installations. 
The cover requires the support frame.

• • •

Cover for Safety kit/hydraulic separator for stand alone boiler

painted metal sheet that protects both the safety manifold and 
the hydraulic separator. 

• • •

Frame kit for front cascades

: it contains all the panels (and 

screws) needed to install the boiler support frame (this kit can be 
used for all Condexa PRO boiler range) .

• • •

2.3 Secondary circuit management

Secondary/tank probe

: NTC probe for temperature control both 

for the tank circuit and for the heating circuit.
Cable length: 2200 mm.

• • •

3-way valve kit for domestic hot water production 50

3-way valve (1" M - kvs = 8.6) to be installed on the boiler return 
(inside the casing).
The kit includes fittings, gaskets, servomotor and electric control 
cable

Electronic management kit for single direct or additional mixed 
zone (max 16)

: kit for the management of additional heating 

zone, direct or mixed. 
It consists of an electronic control device completely wired to the 
terminal board, installed on a DIN bar so that it can be installed in 
a box in the electrical control panel in the central heating.
The electronic module is connected to the boiler board by means 
of a communication bus and allows the management of the zone 
with a dedicated climatic curve.
Feautures:

 

– Direct or mixed zone control

 

– Three way valve management

 

– Zone circulation pump control

 

– Input for TA or OT probe

• • •

Summary of Contents for Condexa Pro 100 P

Page 1: ...Wall hung gas condensing modules Stand alone installation In conformity with Directive 2009 125 EC Condensing thermal modules for indoor applications Modular design to ensure an easy and fast install...

Page 2: ...gime times and maximizing condensation The basic electronics include climate control module cascade management with integrated master slave functions automatic summer winter switching and the possibil...

Page 3: ...Flue gas temperature at max and min power 50 30 C C 45 0 32 0 46 0 33 0 49 0 35 0 Excess air at max power 1 27 1 27 1 27 Excess air at min power 1 27 1 27 1 27 Max min flue gas mass flow rate kg s 0 0...

Page 4: ...gh temperature capacity 4 88 4 88 2 88 2 At 30 of useful heat output and at low temperature capacity 1 98 2 98 0 98 0 AUXILIARY ELECTRICAL CONSUMPTION At full load elmax W 105 77 203 At partial load e...

Page 5: ...0 1 0 1 Flue flow rate kg s 0 020 0 03 0 046 GAS EMISSION VALUES AT MAX AND MIN FLOW RATES G20 MAXIMUM CO s a less than ppm 73 90 92 CO2 9 9 9 NOx EN 677 ppm 30 30 30 Flue temperature C 67 5 72 78 T...

Page 6: ...AYOUT Condexa PRO 50 P Commercial description H mm L mm P mm fumes air mm Net weight kg CONDEXA PRO 50 P 1000 600 435 80 66 CONDEXA PRO 70 P 1000 600 435 80 78 CONDEXA PRO 100 P 1000 600 435 110 81 Fu...

Page 7: ...11 13 14 1 2 3 4 5 6 7 8 9 10 21 19 20 22 23 16 18 24 17 1 2 3 4 5 6 7 8 9 0 7bar 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 10 9 11 12 1 2 3 4 5 6 7 8 18 22 14 20 19 21 16 15 17 23 1 3 4 5 14 2 20...

Page 8: ...ssure switch 5 NTC return probe 6 NTC flow probe 7 Safety thermostat temperature sensor 8 Automatic bleed valve 9 Flow meter F Central heating flow R System return 2 9 M R 1 6 7 8 3 4 5 CIRCULATORS 0...

Page 9: ...the table below DESCRIPTION Condexa PRO 50 P 70 P 100 P A mm 387 387 387 B mm 143 5 143 5 143 5 C mm 63 5 63 5 63 5 D mm 283 5 283 5 283 5 E mm 98 5 98 5 98 5 F mm 92 5 92 5 92 5 H optional 3 way valv...

Page 10: ...6 Max 6 bar Glycol Max 40 only propylene glycol All the data in the table refer to the water contained in the system after 8 weeks operation Do not use excessively softened water Excessive water softe...

Page 11: ...ATURE PROBE ACCESSORY The correct positioning of the external probe is fundamental for the proper functioning of the climate control The probe must be installed outside the building to be heated at ab...

Page 12: ...25 30 10 40 60 70 50 80 90 100 T C Correspondence table valid for all probes CONTROL PANEL 2 1 3 4 5 6 7 9 8 10 1 255x80 backlit display 106 4x39 0mm 2 RESET button allows operation to be restored aft...

Page 13: ...revent contamination do not install suction line air intakes and gas flue extraction pipes near dry cleaners laundry rooms and factories pools metallurgy processing plants beauty parlours fridge repai...

Page 14: ...P 610 32 ACCESSORIES FOR STAND ALONE INSTALLATION GUIDE TO SYSTEM CONFIGURATION WITH STAND ALONE BOILER AND ACCESSORIES SELECTION 1 ACCESSORIES TO COMPLETE THE SYSTEM 2 OPTIONAL ACCESSORIES 2 1 Addit...

Page 15: ...on It allows the hydraulic separation between the primary circuit and the secondary circuit balancing the differences in flow between the circuits This device is necessary on systems equipped with con...

Page 16: ...and the hydraulic separator Frame kit for front cascades it contains all the panels and screws needed to install the boiler support frame this kit can be used for all Condexa PRO boiler range 2 3 Seco...

Page 17: ...and 9 to allow their disposal through the common sewer system The kit is suitable for those systems equipped with a condensate drain in the thermal plant located higher than the condensate discharge o...

Page 18: ...eturn EAF Cold water inlet UAC Domestic hot water outlet Scheme 2 circuit with thermal module connected directly to the heating system and DHW tank check that the pump head is sufficient to ensure ade...

Page 19: ...EAF Cold water inlet UAC Domestic hot water outlet Scheme 4 circuit with thermal module connected with DHW tank and with heating system by means of hydraulic separator 1 Globe valve 2 Non return valve...

Page 20: ...itch 9 Softener filter 10 Pressure reducer 11 Tank 12 Automatic bleed valve 13 Three way valve 14 Circulator 15 High temperature system circulator 16 Tank circulator SE External probe F High temperatu...

Page 21: ...ed on the water circuit Safety thermostat Flowmeter capable of checking continuously the flow rate of the primary circuit and causing the appliance stop in case of insufficient flow Temperature probes...

Page 22: ...nside the packaging the following material is provided Instruction booklet LPG conversion kit Bracket for wall fixing with dowels n 4 dowels d 10mm suitable for concrete bricks compact stone perforate...

Page 23: ...42 630111 Fax 39 0442 630371 www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefor...

Reviews: