Condexa Pro

Image

Description

CONDEXA PRO

50 P 70 P 100 P

1. ACCESSORIES TO COMPLETE THE SYSTEM

External probe

: it contains a probe to be installed in external 

environment, model: NTC 10 kOhm@25°C, used for the climatic mode of 
operation.
N.1 probe for each cascade system, to be wired in the Master boiler.

• • •

2. OPTIONAL ACCESSORIES 
2.1 Safety devices

Manifold kit with safety devices for stand alone installation

: flow 

manifold and housing of the safety devices for Condexa PRO stand 
alone installations.
Accessory installed in the area below the boiler, allowing a 
considerable saving of the space occupied.
kit composed with 3" manifold, insulation and the safety devices 
listed below:
•  Bourdon spring pressure gauge
•  Safety pressure switch for manifold
•  Thermometer 0-120 ° C 1/2 '' G.
•  Safety valve VST 1/2 '' x 3/4 '' 5.4 bar
•  Gas shutting valve (VIC) suitable up to 135 kW

• • •

Hydraulic separator connection kit for stand alone boiler

: flow 

connection pipe.
Accessory installed in the area below the boiler, allowing a 
considerable saving of the space occupied.
Complete with insulation, contains flow connections for both heating 
and DHW circuit.

• • •

2.2 Hydraulic separator or plate heat exchanger

Horizontal hydraulic separator kit for stand alone boiler

: 4" 

hydraulic separator  
with insulation, for Condexa PRO stand alone installation.
It allows the hydraulic separation between the primary circuit and 
the secondary circuit, balancing the differences in flow between 
the circuits.
This device is necessary on systems equipped with control of 
zones by means of thermostatic valves, in which the condition of 
"zero" flow on the secondary circuit can be verified.
Accessory installed in the area below the boiler, allowing a 
considerable saving of the space occupied.
This kit (combined with the safety manifold or with the 
connector-to-the hydraulic separator manifold) acts as a 
compensator / manifold reducing installation costs; therefore 
it allows to have 2 flows (1 for the heating circuit and 1 for the 
storage tank) and 2 returns.

• • •

Plate heat exchanger kit for 50 stand alone boiler

: it consists 

of a braze-welded plate heat exchanger sized with 

D

T

ml

 = 7.2 ° C, 

support bracket and connections to the boiler. This kit requires 
the installation of the support frame kit.

Plate heat exchanger kit for 70 stand alone boiler

: it consists 

of a braze-welded plate heat exchanger sized with 

D

T

ml

 = 7.2 ° C, 

support bracket and connections to the boiler with a manifold 
for three way valve installation (accessory). This kit requires the 
installation of the support frame kit.

Plate heat exchanger kit for 100 stand alone boiler

: it consists 

of a braze-welded plate heat exchanger sized with 

D

T

ml

 = 7.2 ° C, 

support bracket and connections to the boiler with a manifold 
for three way valve installation (accessory). This kit requires the 
installation of the support frame kit.

Summary of Contents for Condexa Pro 100 P

Page 1: ...Wall hung gas condensing modules Stand alone installation In conformity with Directive 2009 125 EC Condensing thermal modules for indoor applications Modular design to ensure an easy and fast install...

Page 2: ...gime times and maximizing condensation The basic electronics include climate control module cascade management with integrated master slave functions automatic summer winter switching and the possibil...

Page 3: ...Flue gas temperature at max and min power 50 30 C C 45 0 32 0 46 0 33 0 49 0 35 0 Excess air at max power 1 27 1 27 1 27 Excess air at min power 1 27 1 27 1 27 Max min flue gas mass flow rate kg s 0 0...

Page 4: ...gh temperature capacity 4 88 4 88 2 88 2 At 30 of useful heat output and at low temperature capacity 1 98 2 98 0 98 0 AUXILIARY ELECTRICAL CONSUMPTION At full load elmax W 105 77 203 At partial load e...

Page 5: ...0 1 0 1 Flue flow rate kg s 0 020 0 03 0 046 GAS EMISSION VALUES AT MAX AND MIN FLOW RATES G20 MAXIMUM CO s a less than ppm 73 90 92 CO2 9 9 9 NOx EN 677 ppm 30 30 30 Flue temperature C 67 5 72 78 T...

Page 6: ...AYOUT Condexa PRO 50 P Commercial description H mm L mm P mm fumes air mm Net weight kg CONDEXA PRO 50 P 1000 600 435 80 66 CONDEXA PRO 70 P 1000 600 435 80 78 CONDEXA PRO 100 P 1000 600 435 110 81 Fu...

Page 7: ...11 13 14 1 2 3 4 5 6 7 8 9 10 21 19 20 22 23 16 18 24 17 1 2 3 4 5 6 7 8 9 0 7bar 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 10 9 11 12 1 2 3 4 5 6 7 8 18 22 14 20 19 21 16 15 17 23 1 3 4 5 14 2 20...

Page 8: ...ssure switch 5 NTC return probe 6 NTC flow probe 7 Safety thermostat temperature sensor 8 Automatic bleed valve 9 Flow meter F Central heating flow R System return 2 9 M R 1 6 7 8 3 4 5 CIRCULATORS 0...

Page 9: ...the table below DESCRIPTION Condexa PRO 50 P 70 P 100 P A mm 387 387 387 B mm 143 5 143 5 143 5 C mm 63 5 63 5 63 5 D mm 283 5 283 5 283 5 E mm 98 5 98 5 98 5 F mm 92 5 92 5 92 5 H optional 3 way valv...

Page 10: ...6 Max 6 bar Glycol Max 40 only propylene glycol All the data in the table refer to the water contained in the system after 8 weeks operation Do not use excessively softened water Excessive water softe...

Page 11: ...ATURE PROBE ACCESSORY The correct positioning of the external probe is fundamental for the proper functioning of the climate control The probe must be installed outside the building to be heated at ab...

Page 12: ...25 30 10 40 60 70 50 80 90 100 T C Correspondence table valid for all probes CONTROL PANEL 2 1 3 4 5 6 7 9 8 10 1 255x80 backlit display 106 4x39 0mm 2 RESET button allows operation to be restored aft...

Page 13: ...revent contamination do not install suction line air intakes and gas flue extraction pipes near dry cleaners laundry rooms and factories pools metallurgy processing plants beauty parlours fridge repai...

Page 14: ...P 610 32 ACCESSORIES FOR STAND ALONE INSTALLATION GUIDE TO SYSTEM CONFIGURATION WITH STAND ALONE BOILER AND ACCESSORIES SELECTION 1 ACCESSORIES TO COMPLETE THE SYSTEM 2 OPTIONAL ACCESSORIES 2 1 Addit...

Page 15: ...on It allows the hydraulic separation between the primary circuit and the secondary circuit balancing the differences in flow between the circuits This device is necessary on systems equipped with con...

Page 16: ...and the hydraulic separator Frame kit for front cascades it contains all the panels and screws needed to install the boiler support frame this kit can be used for all Condexa PRO boiler range 2 3 Seco...

Page 17: ...and 9 to allow their disposal through the common sewer system The kit is suitable for those systems equipped with a condensate drain in the thermal plant located higher than the condensate discharge o...

Page 18: ...eturn EAF Cold water inlet UAC Domestic hot water outlet Scheme 2 circuit with thermal module connected directly to the heating system and DHW tank check that the pump head is sufficient to ensure ade...

Page 19: ...EAF Cold water inlet UAC Domestic hot water outlet Scheme 4 circuit with thermal module connected with DHW tank and with heating system by means of hydraulic separator 1 Globe valve 2 Non return valve...

Page 20: ...itch 9 Softener filter 10 Pressure reducer 11 Tank 12 Automatic bleed valve 13 Three way valve 14 Circulator 15 High temperature system circulator 16 Tank circulator SE External probe F High temperatu...

Page 21: ...ed on the water circuit Safety thermostat Flowmeter capable of checking continuously the flow rate of the primary circuit and causing the appliance stop in case of insufficient flow Temperature probes...

Page 22: ...nside the packaging the following material is provided Instruction booklet LPG conversion kit Bracket for wall fixing with dowels n 4 dowels d 10mm suitable for concrete bricks compact stone perforate...

Page 23: ...42 630111 Fax 39 0442 630371 www riello com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefor...

Reviews: