Riello 7000.1000/S Installation Instructions Manual Download Page 9

9

Riello 7000

Riello 7000 solar storage tanks can be installed in any room where there is no specific requirement for an electrical 

protection rating higher than IP X0D.

   The room where the appliance is installed must, however, be dry to prevent the formation of rust.

   Respect the minimum specified installation distances to ensure correct installation and access for maintenance

When installing Riello 7000 solar storage tanks in old systems or systems requiring modernisation, always perform the 

following checks:

- Make sure that the system is fitted with safety and control devices in accordance with applicable legislation and 

standards.

- Make sure that the system has been flushed out to remove all sludge and lime scale, and has been vented and seal 

tested.

1

2

1

1

Riello 7000.2000/F - 3000/F - 5000/F

Riello 7000.1000/S - 1500/S

Make sure that any lifting equipment is of adequate capa-

city to lift and move the storage tank.

Cut the straps (1) to remove the tank from the pallet.

On Riello 7000.1000/S e 1500/S models the straps are loca-

ted under the insulation at the hinges.

The storage tanks are fitted with a plug (2) into which you 

can screw a lifting eyebolt (Ø 10 mm). Make sure that the 

eyebolt is strong enough to lift the weight of the tank.

To lift Riello 7000.2000/F - 3000/F - 5000/F storage tanks, 

first remove the insulation, then attach a rope of adequa-

te strength to the top of the tank before proceeding to lift 

with great care.

   Wear suitable personal protective equipment and 

use suitable safety devices.

    Do not leave packaging material within the reach of 

children, since it can become a potential hazard.

10   Handling

11   Place of installation

12   Installation in older systems and systems requiring modernisation

Summary of Contents for 7000.1000/S

Page 1: ...cod 068549EN rev 8 06 2015 Solar storage tanks 7000 EN INSTALLATION INSTRUCTIONS...

Page 2: ...ng of your Riello 7000 solar storage tank Please accept our renewed thanks for your purchase Riello MODEL CODE RIELLO 7000 1000 S 4383408 RIELLO 7000 1500 S 4383409 RIELLO 7000 2000 F 4383410 RIELLO 7...

Page 3: ...pylene glycol with water in a percentage varying from 30 to 50 as instructed in the relevant Riello installation and maintenance manual Only fill the solar heating system with water and glycol premixe...

Page 4: ...f coil Maximum working pressure of cylinder Maximum working temperature of cylinder Heat loss Electrical consumption Power supply l kW l 1 bar C bar C kW 24h W V Hz Obligatory ground connection Serial...

Page 5: ...il Riello 7000 1000 S and 1500 S models Riello 7000 2000 F 3000 F 5000 F models 1 Soft polyurethane insulation 100 mm 2 Vent outlet fitting 1 1 4F 3 Outlet return fittings 1 1 2F 4 Probe wells 1 2 F 7...

Page 6: ...ange diameter external internal 290 220 290 220 290 220 mm Probe well diameter 8 mm Coil water capacity 14 6 21 6 l Coil heat exchange surface area 2 6 3 8 m2 Power absorbed by coil 68 99 kW Heating h...

Page 7: ...000 2000 F 3000 F 5000 F models Heat exchanger coil KIT PRESSURE DROP Riello 7000 2000 F 3000 F 5000 F models only PRESSURE DROP mbar FLOW RATE m3 h 8 Dimensions and weight Riello 7000 1000 S Riello 7...

Page 8: ...The counter flange comes ready bolted to the tank s flange and fitted with a seal The second package contains another plastic bag with the elegantly finished polyurethane insulation fitting sleeves f...

Page 9: ...1 2 1 1 Riello 7000 2000 F 3000 F 5000 F Riello 7000 1000 S 1500 S Make sure that any lifting equipment is of adequate capa city to lift and move the storage tank Cut the straps 1 to remove the tank...

Page 10: ...e holes on the inside of the insulation Secure the insulation in place with the zips 2 at the edges of the two sections Perforate the insulation at the fittings and fit the insu lation sleeves 3 Fit t...

Page 11: ...iler OFF at the main switch and at the control panel Close the shut off cocks for the heating water circuit Drain the storage tank or its secondary circuit if a pri mary circuit is connected EXTERNAL...

Page 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...

Reviews: