4

Riello 7000

Riello 7000 solar storage tanks are identified by three plates. (On models Riello 7000.2000/F - 3000/F - 5000/F  these 

must be applied by the installer after the insulation has been fitted, see page 20).

    If these plates or any other means of clearly identifying the product 

are defaced, removed or lost, proper installation and servicing may be 

rendered difficult.

- Data plate

  This lists the technical specifications and performan-

ce of the product.

- Product identification plate

  This bears the name of the product.

- Serial number plate

  This specifies the serial number, model, consumption

   and capacity.

Model

Code

Serial

number

Year of manufacture

SOLAR STORAGE CYLINDER

Storage cylinder capacity

Maximum absorbed power [Primary T = 80

°

C]

Specific flow rate [

Δ

T 35

°

C]

Maximum working pressure of coil

Maximum working temperature of coil

Maximum working pressure of cylinder

Maximum working temperature of cylinder

Heat loss

Electrical consumption

Power supply

l

kW

l/1'

bar

°

C

bar

°

C

kW/24h

W

V-Hz

Obligatory ground connection

Serial

number

Model

Storage cylinder

capacity

l

kW

Maximum

absorbed power

Model

Code

Serial

number

Year of manufacture

SOLAR STORAGE CYLINDER

Storage cylinder capacity

Maximum absorbed power [Primary T = 80

°

C]

Specific flow rate [

Δ

T 35

°

C]

Maximum working pressure of coil

Maximum working temperature of coil

Maximum working pressure of cylinder

Maximum working temperature of cylinder

Heat loss

Electrical consumption

Power supply

l

kW

l/1'

bar

°

C

bar

°

C

kW/24h

W

V-Hz

Obligatory ground connection

Serial

number

Model

Storage cylinder

capacity

l

kW

Maximum

absorbed power

ACCUMULO INERZIALE

Riello  7000  solar  storage  tanks  are  specifically  designed 

for integration in central heating systems (not for DHW 

use).

The most important technical features of these storage 

tanks are:

-  The tank and coils (Riello 7000.1000/S and 1500/S models 

only) are specially designed and shaped for optimum 

performance  in  terms  of  stratification,  heat  exchange 

and replenishment times.

-  Water fittings are available at different heights, permit-

ting different hot water generators to be used without 

reducing the stratification effect.

-  CFC-free polyurethane insulation and an elegant exter-

nal coating reduce heat loss and improve efficiency.

-  A flange is provided for easy cleaning and to allow an 

extra heat exchanger to be added (Riello 7000.2000/F - 

3000/F - 5000/F models only).

Riello 7000 storage tanks can be connected to a special 

solar controller and can be integrated in solar heating sy-

stems in which Riello boilers or water heaters serve as au-

xiliary heat generators. A heat exchanger for installation 

on  the  flange  is  available  separately  for  the  Riello  7000 

.2000/F - 3000/F - 5000/F model.

3   Product description

4   Identification

Riello S.p.A.
Via degli Alpini 1
37045 Legnago (VR) - Italy

Riello S.p.A.
Via degli Alpini 1
37045 Legnago (VR) - Italy

Summary of Contents for 7000.1000/S

Page 1: ...cod 068549EN rev 8 06 2015 Solar storage tanks 7000 EN INSTALLATION INSTRUCTIONS...

Page 2: ...ng of your Riello 7000 solar storage tank Please accept our renewed thanks for your purchase Riello MODEL CODE RIELLO 7000 1000 S 4383408 RIELLO 7000 1500 S 4383409 RIELLO 7000 2000 F 4383410 RIELLO 7...

Page 3: ...pylene glycol with water in a percentage varying from 30 to 50 as instructed in the relevant Riello installation and maintenance manual Only fill the solar heating system with water and glycol premixe...

Page 4: ...f coil Maximum working pressure of cylinder Maximum working temperature of cylinder Heat loss Electrical consumption Power supply l kW l 1 bar C bar C kW 24h W V Hz Obligatory ground connection Serial...

Page 5: ...il Riello 7000 1000 S and 1500 S models Riello 7000 2000 F 3000 F 5000 F models 1 Soft polyurethane insulation 100 mm 2 Vent outlet fitting 1 1 4F 3 Outlet return fittings 1 1 2F 4 Probe wells 1 2 F 7...

Page 6: ...ange diameter external internal 290 220 290 220 290 220 mm Probe well diameter 8 mm Coil water capacity 14 6 21 6 l Coil heat exchange surface area 2 6 3 8 m2 Power absorbed by coil 68 99 kW Heating h...

Page 7: ...000 2000 F 3000 F 5000 F models Heat exchanger coil KIT PRESSURE DROP Riello 7000 2000 F 3000 F 5000 F models only PRESSURE DROP mbar FLOW RATE m3 h 8 Dimensions and weight Riello 7000 1000 S Riello 7...

Page 8: ...The counter flange comes ready bolted to the tank s flange and fitted with a seal The second package contains another plastic bag with the elegantly finished polyurethane insulation fitting sleeves f...

Page 9: ...1 2 1 1 Riello 7000 2000 F 3000 F 5000 F Riello 7000 1000 S 1500 S Make sure that any lifting equipment is of adequate capa city to lift and move the storage tank Cut the straps 1 to remove the tank...

Page 10: ...e holes on the inside of the insulation Secure the insulation in place with the zips 2 at the edges of the two sections Perforate the insulation at the fittings and fit the insu lation sleeves 3 Fit t...

Page 11: ...iler OFF at the main switch and at the control panel Close the shut off cocks for the heating water circuit Drain the storage tank or its secondary circuit if a pri mary circuit is connected EXTERNAL...

Page 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...

Reviews: