co
d.
0
6
85
49
EN
r
e
v.
8
06
/20
15
Solar storage tanks 7000
INSTALLATION INSTRUCTIONS
Page 1: ...cod 068549EN rev 8 06 2015 Solar storage tanks 7000 EN INSTALLATION INSTRUCTIONS...
Page 2: ...ng of your Riello 7000 solar storage tank Please accept our renewed thanks for your purchase Riello MODEL CODE RIELLO 7000 1000 S 4383408 RIELLO 7000 1500 S 4383409 RIELLO 7000 2000 F 4383410 RIELLO 7...
Page 3: ...pylene glycol with water in a percentage varying from 30 to 50 as instructed in the relevant Riello installation and maintenance manual Only fill the solar heating system with water and glycol premixe...
Page 4: ...f coil Maximum working pressure of cylinder Maximum working temperature of cylinder Heat loss Electrical consumption Power supply l kW l 1 bar C bar C kW 24h W V Hz Obligatory ground connection Serial...
Page 5: ...il Riello 7000 1000 S and 1500 S models Riello 7000 2000 F 3000 F 5000 F models 1 Soft polyurethane insulation 100 mm 2 Vent outlet fitting 1 1 4F 3 Outlet return fittings 1 1 2F 4 Probe wells 1 2 F 7...
Page 6: ...ange diameter external internal 290 220 290 220 290 220 mm Probe well diameter 8 mm Coil water capacity 14 6 21 6 l Coil heat exchange surface area 2 6 3 8 m2 Power absorbed by coil 68 99 kW Heating h...
Page 7: ...000 2000 F 3000 F 5000 F models Heat exchanger coil KIT PRESSURE DROP Riello 7000 2000 F 3000 F 5000 F models only PRESSURE DROP mbar FLOW RATE m3 h 8 Dimensions and weight Riello 7000 1000 S Riello 7...
Page 8: ...The counter flange comes ready bolted to the tank s flange and fitted with a seal The second package contains another plastic bag with the elegantly finished polyurethane insulation fitting sleeves f...
Page 9: ...1 2 1 1 Riello 7000 2000 F 3000 F 5000 F Riello 7000 1000 S 1500 S Make sure that any lifting equipment is of adequate capa city to lift and move the storage tank Cut the straps 1 to remove the tank...
Page 10: ...e holes on the inside of the insulation Secure the insulation in place with the zips 2 at the edges of the two sections Perforate the insulation at the fittings and fit the insu lation sleeves 3 Fit t...
Page 11: ...iler OFF at the main switch and at the control panel Close the shut off cocks for the heating water circuit Drain the storage tank or its secondary circuit if a pri mary circuit is connected EXTERNAL...
Page 12: ...0442630111 Fax 044222378 www riello it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore lia...