GENERAL
10
(**) Specified data must not be used to certify the system. Certificates must state the values listed in the “System Service
Booklet” as measured on initial start-up.
Description
RESIDENCE COLONNA CONDENS
KV/130 30 ISC
Type of storage cylinder
Vitrified
Cylinder layout
Vertical
Heat exchanger layout
Vertical
Maximum power absorbed by heat exchanger
28
kW
DHW temperature setting range
35-60
°C
Storage cylinder capacity
130
l
Heat exchanger surface area
5,5
l
Coil water capacity
0,91
m
2
DHW production
∆T 25°C
15
l/min
∆T 35°C
10
l/min
Water draw in 10 minutes with stor-
age cylinder at
48°C (**)
176
l
60°C (**)
229
l
Specific flow rate (EN625)
25,1
l/min
Maximum operating pressure of storage cylinder
8
bar
Volume of expansion vessel (DHW)
6
l
Precharge of expansion vessel (DHW)
2,5
bar
Description
RESIDENCE COLONNA CONDENS
KV/130 30 ISC
Function parameters for G20
Lower Wobbe index (at 15°C - 1013 mbar)
45,67
MJ/m
3
s
Rated supply pressure
20
mbar
Minimum supply pressure
10
mbar
Gas diaphragm
6,7
mm
Maximum gas flow rate, DHW/CH
3,17
Sm
3
/h
Minimum gas flow rate, DHW/CH
0,63
Sm
3
/h
Maximum fan speed, DHW/CH
6000
rpm
Minimum fan speed
1600
rpm
Burner ignition slow fan speed
3400
rpm
Function parameters for G31
Lower Wobbe index (at 15°C - 1013 mbar)
70,69
MJ/m
3
s
Rated supply pressure
37
mbar
Minimum supply pressure
35
mbar
Gas diaphragm
4,7
mm
Maximum gas flow rate, DHW/CH
2,33
Sm
3
/h
Minimum gas flow rate, DHW/CH
0,47
Sm
3
/h
Maximum fan speed, DHW/CH
6000
rpm
Minimum fan speed
1600
rpm
Burner ignition slow fan speed
3400
rpm