- 28 -
Alarm-relay activation time:
The time of activation of the free exchange C – NC – NO of alarm relay and of oSA and +S can be
set with following values:
7
P
I
D
e
m
i
t
m
r
a
l
A
F
F
O
s
d
n
o
c
e
s
0
6
N
O
s
d
n
o
c
e
s
0
8
1
Number of areas:
It is possible to manage a single area in three different arming modes. (ON, HOME and AREA) or two
areas, in this latter case arming modes can be two for main area (ON and HOME) and 1 for the
secondary area (ON):
It is necessary to set the number of the areas before proceeding to acquisition of MASTER keys
8
P
I
D
s
a
e
r
a
f
o
s
r
e
b
m
u
N
F
F
O
a
e
r
a
1
N
O
s
a
e
r
a
2
PROGRAMMING, SECOND LEVEL (THROUGH JUMPERS S1 AND S2):
The functions programmable through jumpers S1 and S2 are the following:
•
Acquisition and cancellation of proximity keys
•
Association of the zones to arming and/or areas
•
Zone adjusting Switch Alarm
INPUT IN PROGRAMMING, SECOND LEVEL:
•
Ensure that both areas are disarmed
•
Press and keep pressed pushbutton PB on front of control panel
•
A.
First access: insert any proximity key into the RD reader on control panel
In order to then have access to programming, it is necessary to have at least one MASTER
key acquired by the RD reader on control panel
B.
Following accesses: insert one MASTER key into the RD reader on control panel
•
As soon as the Battery Led starts blinking, release and repress quickly the PB pushbutton keeping
the proximity key into RD reader.
•
If the procedure is accepted there will be blink of all area Led at the same time
•
Remove the key from RD reader and release PB pushbutton
•
A time-lapse of 40 seconds is activated during which the Battery Led blinks continuously. During
this time-lapse and during the whole programming permanence, the control panel Tamper and zone
1 if programmed as 24 hours, will be excluded.
•
Open control panel housing
•
Place jumpers S1 and S2 according to the programming to make.
Programming remains active until jumper S1 remains inserted in any position and for further
40 seconds since when it is opened.
Acquisition of proximity keys (max 8 for Lucky 4 and max 16 for Lucky 8):
During this procedure, all RS readers connected to RS485 serial are acquired.
•
Close jumper S1 in position 4 on control panel board
•
Approach the key to acquire to a reader associated to the operating area.
• RS Readers:
Led 2 Red it blinks slowly if the key is correctly acquired
Led 2 Red blinks quickly if the key has already been memorized
Led 1 and Led 3 Red the blink quickly if the key-memory is full
•
RD on control panel
Led Tamper blinks slowly if the key is correctly acquired
Led Tamper blinks quickly if the key has been memorized already
Led ON and Battery blink quickly if the key memory is full
•
Keeping jumper S1 in position 4, approach the sequence of all keys to the readers associated to their
operating areas.
•
Once acquired all keys, re-open jumper S1
To change from a one-area system to a two-areas system, it is necessary to cancel and re-
acquire all keys, included those acquired as MASTER keys.
E
N
G