- 29 -
Cancellation of proximity keys
This procedure allows cancellation of all proximity keys memorized. It is not possible to cancel single keys.
•
On the control panel board, close jumper S1 in position 4
•
Press and keep pressed pushbutton PB1 until Led BATT changes blinking frequency to show
completion of cancellation request
•
Release pushbutton PB
Association of zones to arming and/or areas
With this procedure, zones are associated to various modes of arming and, in case of use of 2 areas,
which ones have to be associated to area 2.
•
Close Jumper S1 to position 2 on control panel
•
To associate the zones to various arming and/or to area 2:
• With 1 area : arming HOME: keep jumper S2 open
• With 1 area : arming AREA: close jumper S2 to position P2
• With 2 areas: arming HOME area 1: keep jumper S2 open
• With 2 areas: arming area 2: close jumper S2 to position P2
•
Zones Led give automatic sequence
•
As soon as the led of the zone to associate or de-associate to selected arming/area starts blinking,
press and release pushbutton PB
•
Repeat for all zones to associate to selected arming/area
•
Reopen jumper S2
Adjustment of switch alarm zones
Configuration of zones 4 and 5 can be as “switch alarm” to manage directly inertial sensors and/or
“wire” contacts.
Even if the configuration of zones balance is with DIP 5 in OFF (normally closed), the configuration
of the zones as “switch alarm” have to be necessarily balanced with the 4700 ohm resistance
Proceed to configuration of switch alarm zones and their sensitivity following these steps:
•
Close jumper S1 to position 3 on control panel
• For configuration of zone 4 close jumper S2 to position P1
• For configuration of zone 5 close jumper S2 to position P2 (Lucky 8 only)
•
Press pushbutton PB several times until reaching the level sensitivity wished, visualized by lighting
up of zone led from 1 to 4 on Lucky 4 and from 1 to 7 on Lucky 8, and keeping in mind that the
bigger is the number of led ON the lower is the sensitivity.
• Furthermore, only on Lucky 8, at any pressure of pushbutton PB, the “memory” function activates
and de-activates
With Memory excluded, only consequent pulses are counted, with Memory included all pulses are
counted, also the non consequent ones occurred in a certain lapse of time. With Memory active, the
zone led 8 is blinking, with Memory excluded the zone led 8 is off.
• Lucky 4: with minimum sensitivity (zone led from 1 to 4 are on) a further pressure on pushbutton PB
brings the zone to immediate mode (all zone led are off).
• Lucky 8: with minimum sensitivity and memory included (zone led from 1 to 7 are on and led 8 is
blinking ) a further pressure of pushbutton PB put the zone in immediate mode (all zone led are off).
•
Re-open jumper S2
LEAVING PROGRAMMING, SECOND LEVEL
•
At the end of programming, re-open jumper S1
•
A time lapse of 40 seconds is activated, during which the Battery led continues blinking . close
control panel box and wait to leave from programming, shown by switching off of Battery led . At the
end of battery led blinking, the control panel tamper and zone 1 if programmed as 24 hours, are re-
activated.
E
N
G