# Design types for cold holding
Cooling range -
12
°C to +
8
°C with door closed. Refrigerant 134a.
Designation
Control
Connected load
Degree of protec
tion of enclosure
Dimensions
BxTxH/
unladen weight
Order no
BKW-KF, one door, 1 x 2/1 GN
vertical clearance between rails 115
Electronic
control
600 Watt
IP X3
802 x 884 x 1765
150 kg
88 23 04 02
BKW–KF, two doors, 2 x 2/1 GN
vertical clearance between rails 115
Electronic
control
600 Watt
IP X5
1483 x 843 x 1765
215 kg
88 23 04 01
# Storage capacity
BKW 1 x 2/1GN heated
vertical clearance between rails 115
BKW 1 x 2/1 GN heated
vertical clearance between rails 70
Plates stacked Ø 260
mm
64
64
Plates not stacked Ø 260
mm
44
72
Plates not stacked Ø 310
mm
22
36
BKW 2 x 2/1 GN heated
vertical clearance between rails 115
BKW 2 x 2/1 GN heated
vertical clearance between rails 70
Plates stacked Ø 260
mm
160
160
Plates not stacked Ø 260
mm
110
180
Plates not stacked Ø 310
mm
88
144
BKW –KF 1 x 2/1 GN refrigerated
vertical clearance between rails 115
BKW –KF 2 x 2/1 GN refrigerated
vertical clearance between rails 115
Plates not stacked Ø 260
mm
40
88
Plates not stacked Ø 310
mm
20
44
Further specifications:
See catalogue, brochure
5.3
Accessories
User tip
With perfect accessories, you will achieve high energy efficiency and can use a wider
range of applications.
Use accessories from Rieber GmbH & Co. KG.