English – 17
Individual Components
Self-Leveling Camera
The bearings and weight of the self-leveling camera may
create a swinging effect when you push the push cable
through the pipe. The camera image settles quickly when
the push cable is steady.
The self-leveling camera can be removed to trouble-
shoot problems, send for repair, or to replace. Refer to
Appendices C and D for instructions on how to remove
and install the camera head.
System Cable Assembly
The system cable assembly includes the system connec-
tor, for connecting to SeeSnake digital reporting moni-
tors; 3 m [10 ft] of system cable; and the slip-ring assem-
bly, which is made up of the slip-ring dial and the slip-ring
cavity on the frame.
Before cleaning the Compact2, ensure the slip-ring dial
is locked in the slip-ring cavity. Avoid getting the slip-
ring assembly wet when cleaning.
NOTICE
To avoid damaging the slip-ring contact
pins or getting the internal electrical
components wet, keep the slip-ring as-
sembly locked.
System Cable Removal
1. Disconnect the system cable from the reporting
monitor and remove the monitor from the docking
system.
2. Unwrap the system cable from the cable wraps.
3. Pop the frame cable anchor off the frame and un-
hook the system cable from the frame hook.
Cable Anchor
Frame Hook
4. Turn the slip-ring dial counter-clockwise to the un-
locked position .
5. Pull straight out.
NOTICE
Do not touch the contact pins inside the
slip-ring dial. Stressing the contact pins
can cause them to break.
Broken Contact Pin