Resistance (Autoranging)
Range
Resolution
Accuracy
400.0 Ω
0.1 Ω
±1.2% of Reading ± 4 Digits
4.000 kΩ
1 Ω
±1.0% of Reading ± 2 Digits
40.00 kΩ
10 Ω
±1.2% of Reading ± 2 Digits
400.0 kΩ
100 Ω
4.000 MΩ
1 kΩ
40.00 MΩ
10 kΩ
±2.0% of Reading ± 3 Digits
Input Protection ..............................................600V DC or 600V AC RMS
Capacitance (Autoranging)
Range
Resolution
Accuracy
4.000 nF
1 pF
±5.0% of Reading ± 0.5 nF
40.00 nF
10 pF
±5.0% of Reading ± 7 Digits
400.0 nF
0.1 nF
±3.0% of Reading ± 5 Digits
4.000 uF
1 nF
40.00 uF
10 nF
200.0 uF
0.1 uF
±5.0% of Reading ± 5 Digits
Input Protection ..............................................600V DC or 600V AC RMS
Frequency (Autoranging)
Range
Resolution
Accuracy
9.999 Hz
0.001 Hz
±1.5% of Reading ± 5 Digits
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
±1.2% of Reading ± 3 Digits
9.999 kHz
1 Hz
99.99 kHz
10 Hz
999.9 kHz
100 Hz
9.999 MHz
1 kHz
±1.5% of Reading ± 4 Digits
Sensitivity ..........................................................> 0.5 V RMS while ≤ 100kHz
Sensitivity ..........................................................> 8 V RMS while > 100kHz
Overload protection ......................................600V DC or AC RMS
Duty Cycle
Range
Resolution
Accuracy
0.1% to 99.9%
0.1%
±1.2% of Reading ± 2 Digits
Pulse Width .......................................................> 100 µs, < 100 MS
Frequency Width ............................................5 Hz to 150 kHz
Sensitivity ..........................................................>0.5 V RMS
Overload protection ......................................600V DC or AC RMS
Temperature
Range
Resolution
Accuracy
-20°C to +760°C
1°C
±3% of Reading ± 5°C / 9°F
-4 °F to +1400 °F
1°F
Sensor..................................................................Type K Thermocouple
Overload protection ......................................600V DC or AC RMS
Diode Test
Range
Resolution
Accuracy
0.3 mA Typical
1 mV
±10% of Reading ± 5 Digits
Open Circuit Voltage .....................................1.5 V DC Typical
Overload protection ......................................600V DC or AC RMS