![Ricoh Streamline NX Technical Bulletin Download Page 94](http://html1.mh-extra.com/html/ricoh/streamline-nx/streamline-nx_technical-bulletin_1456746094.webp)
T
echnical
B
ulletin
PAGE: 4/7
Reissued: 10-Dec-14
Model:
Streamline NX
Date:
14-Nov-14
No
.: RD639008e
Version
Modified Points or Symptom Corrected
D6399911B folder. This is because SLNX v2.2.1 installation media includes
SPM-E v2.2.0, which can be affected by compatibility problems with SPM-S
v2.1.1/v2.1.2.
Important: Please reboot the device after the overwrite-installation of the
MET-C1 (MP C2003/C2503) SDK application. After the overwrite-installation
of the SDK application, SC997 can sometimes occur on device. Please be
sure to reboot the device by either of the following procedures in order to
recover from SC997:
- Manually reboot the device by using the hardware switch.
- Reboot the device with WIM (WIM -> Device Management -> Reset the
Machine).
-
SLNX can distribute the "Device Template" to the devices to force a
reboot. Distribute the "Device Template" to the devices to overwrite the
SNMP community name with the current value. A device reboot is
always performed if the SNMP community name is updated.
For LP:
This patch does not include support for new LP models. Thus, the original
version’s SDK applications can be used.
NOTE: After rebooting, the SDK application and device can be used
normally without issue.
Update Patch
for ADM
1.0.1
Supported:
-
The models supported in SLNX v2.2.0 have been added.
-
After applying the patch, suffix “c” is added to the ADM version (v2.1.x.c,
for example).
This patch can be applied to the following PC application versions:
From
-
RICOH Streamline NX v2.0.1.0 Administration Manager
To
-
RICOH Streamline NX v2.2.1.x Administration Manager
-
Versions with a previously released patch applied (v2.0.1a and v2.1.x.a)
Please apply the patch by following the procedure described in the
“readme”
file bundled with the object. After the patch is applied, SLNX will support the
following models:
Model Name
Product Name
Supported
Standard
SLNX version
Model K-C4
MP 2001/MP2501 (4.3-inch
panel)
2.1.2
Model CH-C1
MP C6502/MP C8002
2.1.2
Model MET-
C1ab
MP C3003/MP C3503
2.1.2
Model MET-
MP C4503/MP C5503/MP C6003
2.1.2