Page 2: ...ed trademark of RATIO Entwicklungen GmbH Hamburg Germany Calcomp is a registered trademark of Calcomp Inc CALS is a registered trademark of U S Department of Defense USA CGM is a registered trademark...

Page 3: ...sequence 18 Name conventions 18 From the drawing to the job 20 Job and entry in the chart 21 Tools 23 Main symbol bar 23 Icon bar 24 Presets 26 Setting the SSL defaults 26 General tab 26 Set up SSL sp...

Page 4: ...lcomp Pens 63 Calcomp Colors 65 Calcomp Misc 66 Collate jobs 70 Add entries 71 Add with button 71 Add using the right hand mouse button 72 Add with menu item 72 Add with Drag Drop 73 Add multiple entr...

Page 5: ...7 Main tab 97 Job Data tab 99 Advanced tab 99 Options tab 102 PART IV RW 480 PLOTCLIENT WEB 103 Introduction 104 Installation 105 Configuration 107 Open the configuration page 107 Access rights for us...

Page 6: ...MAC 136 Installations 137 Installations on Server PC with Windows 137 Installation on the Macintosh computer 138 Print jobs and presets 139 MainOptions 1 139 MainOptions 2 140 JobOptions 141 PART VI R...

Page 7: ...CONTENTS Index 151 RW 480 CLIENTS 7...

Page 8: ...apters RW 480 PLOTCLIENT WIN RW 480 PLOTCLIENT WIN is available for Microsoft Windows NT 4 0 Microsoft Windows 2000 Microsoft Windows XP and Microsoft Windows 95 98 ME and is a program for preparing p...

Page 9: ...tion RW 480 PLOTCLIENT MAC With the printer driver RW 480 PLOTCLIENT MAC you can send print jobs to RW 480 PLOTBASE from applications which run on the Macintosh operating system Mac OS 10 3 RW 480 PL...

Page 10: ...are free to decide whether you wish to fol low the recommendation given in a note or not Notes are usually used to draw your attention to special cir cumstances or even to point out useful commands or...

Page 11: ...Part I RW 480 PLOTCLIENT WIN RW 480 CLIENTS 11...

Page 12: ...llating set based jobs The Client Server architecture of RW 480 PLOTBASE enables each connected user to define their print jobs and drawing sets themselves and to send them to RW 480 PLOTBASE for outp...

Page 13: ...indows NT 4 0 Microsoft Windows 95 98 ME Microsoft Internet Explorer 5 0 or higher Network interface Configuration 10 100 Base T Ethernet the TCP IP configuration is necessary Processor System memory...

Page 14: ...on Next 8 Choose the setup type that you prefer and click on Next 9 Specify the network spool path and click on Next The first part Server indicates the target computer on which RW 480 PLOTBASE is ins...

Page 15: ...INSTALLATION a job example which you can send off straight away as the first print job RW 480 CLIENTS 15...

Page 16: ...symbol Your first sample print is easy to manage and will already be started at the end of your installation For explanations you will have to read in following two chapters From the drawing to the j...

Page 17: ...PROGRAM WINDOW Program window RW 480 CLIENTS 17...

Page 18: ...omplied using RW 480 PLOTCLIENT WIN and can include an unlimited number of entries User The user or job producer prepares the jobs with RW 480 PLOTCLIENT WIN The user can simultaneously be the client...

Page 19: ...either a full version from AutoCAD series 2000 to 2006 or the DWF DWG DXF option Note RW 480 PLOTBASE cannot print DWG and DXF files that contain several single files SSL file The SSL file is automati...

Page 20: ...swoman produces the draw ing using an EDM CAD or similar system and saves it in one of the following formats which are identified by RW 480 PLOTBASE from the file extension Calcomp 906 907 CALS MIL ST...

Page 21: ...em via the network LAN to the directories pro vided using the program command File Print SSL thereby making them available for RW 480 PLOTBASE to print 6 COLLECTION RW 480 PLOTBASE regularly reads the...

Page 22: ...ob creator e g control view priority format medium copies margin job entry 1 entry 2 entry x SSL file includes as required change of priority format medium copies margin completed job customer create...

Page 23: ...ditor with the main symbol bar and use the icon bar for the file preview Main symbol bar Send job to the SSL spool folder View and selection of the SSL spool path Open view information for the current...

Page 24: ...ely reduce drawing Switch drawing to zoom all Switch drawing to view 1 1 Multipage document View first page Multipage document Back one page Multipage document Enter destination page Multipage documen...

Page 25: ...TOOLS Display drawing in preview lighter if gray display has no effect on printing Display drawing in preview darker if gray display has no effect on printing RW 480 CLIENTS 25...

Page 26: ...re to be the standard values for all SSL print jobs Also after the first program start these default values can be changed whenever you wish Simply open the job editor via the menu item Settings SSL d...

Page 27: ...spool path in two stages Firstly on the left enter the name of the server PC to which your plotter is connected so that the RW 480 PLOTCLIENT WIN can collect the necessary SMNP device in formation of...

Page 28: ...ed above but have several different print jobs To be able to send more than one print job in only one file via e mail RW 480 PLOTCLIENT WIN can compress all jobs in one single file which is stored in...

Page 29: ...enters the server PC and the spool paths established here in the window Plot Path 3 If you can see several spool paths in the window Plot Path select one of these and then click on Set so that the rig...

Page 30: ...ard value in RW 480 PLOTCLIENT WIN and all conversions in a conversion of size units always refer to 600 DPI After each print job you can also have displayed where the program has filed the compressed...

Page 31: ...rmation Device This displays all the units connected numbered from Printer 0 to Printer x In the current program version however only one plot ter is ever connected State The State displays general in...

Page 32: ...e g pa per transparency foil or film Filling This shows you how much material remains i e how much pa per transparency etc is still available on the reel Width This shows the actual width of the mediu...

Page 33: ...the language of the program you can do that quickly and easily in three stages in Windows without any further adjustments 1 Open the language setting using the menu point Settings Language 2 Adjust th...

Page 34: ...the drawing header Job settings area This section describes the general settings for all jobs which can be adjusted on the two cards Job Specific and Job Additional Job Specific tab On the Job Specifi...

Page 35: ...or the re ceiver of the invoice in house Notes This field is free for your notes You can enter up to maximum 50 characters Please do not use any quotation marks Distribution In this field you enter wh...

Page 36: ...lowing successful job comple tion To send an email enter the email address of the user Sample Print Activate this option if you want to check the quality of a print off Only the first set of copies wi...

Page 37: ...tter RW 480 front and rear The standard setting is output at the front Locked Print If you have important print jobs which others should not be able to see activate the Security option Your job can th...

Page 38: ...480 PLOTBASE can send one or several documents for later printout The documents are saved in the document server memory until they are printed out directly at the plotter or the job is deleted in the...

Page 39: ...ert a special medium in the plotter The print job is marked blue in the job list Direction Finally indicate the order for printing the individual pages on the sheet The Z direction prints the pages li...

Page 40: ...ponding job the plotter will demand the password stated here Default settings area The following chapters explain which default settings you can set for the entries The default settings only apply for...

Page 41: ...nts You can use the Window if you set a standard format e g ISO A0 and want to extend the format width and format height First set the required format and then click in Window You can now change the S...

Page 42: ...is Format If you don t activate For mat the plotter cuts the drawing immediately after the last data has been printed it means synchronous This results in optimum paper or medium use because it produc...

Page 43: ...the plotter chooses the input tray which matches the format size of the drawing Should this input tray be empty the plotter uses the tray roll with the next largest format Invert If you activate this...

Page 44: ...anslucence has been scanned with mirror inversion to in crease the contrast Entry settings area You can read here which adjustments can be made for an indi vidual entry If you want to alter the settin...

Page 45: ...ngs button When an entry or a drawing is marked the program automatically identifies the format and opens the Calcomp or HPGL settings itself Please read the separate sections on the pen settings for...

Page 46: ...ngs and Data tabs You can define as many stamps as you like per drawing Make stamp This chapter describes how you can name and save new stamps Proceed as follows to configure a new stamp 1 The first s...

Page 47: ...n its own Stamp File It can then be used at any time for producing a new stamp which you would like to use for o ther entries The stamp files have the file extension stp and it is advisable that this...

Page 48: ...tion X mirror The text is mirrored horizontally Y mirror The text is mirrored vertically XY mirror The text is mirrored about both axes simultaneously which equates to a rotation of 180 Rotation The s...

Page 49: ...TBASE in the configuration program and it is displayed at the bottom of the screen in the status bar Scale position With the Scale position you determine whether the stamp al ways retains its position...

Page 50: ...colored symbol you let the program know that there is a logo and activate the Logo orientation field Text In this text field you can enter the text to be Printed with your stamp In the text field you...

Page 51: ...ntry on which the stamp s are printed The following macros are avail able Date With this macro RW 480 PLOTCLIENT WIN inserts the current date of the print File title This macro only gives the actual f...

Page 52: ...or graduations are only available if you have adjusted the stamp types opaque or transparent Logo Select a graphic using the Browse button which is to appear in the stamp as a logo For example your fi...

Page 53: ...efaults settings you must use the separate Calcomp settings and HPGL settings buttons because a job can contain several drawings with different formats If you alter the settings for an entry RW 480 PL...

Page 54: ...widths have only slightly changed Note It is possible that if you change colors you will not see any large changes in the preview file if you only change from 50 gray to 60 gray for gray shades say C...

Page 55: ...individual pen color should only be considered as being a symbolic equivalent for a gray scale value Each color is equivalent to a value of gray thus e g yellow could be rep resented by 10 Gray red wi...

Page 56: ...ed to each color If you do not want to change each color you can set all pens to Gray on the Pen tab and there you can set the individual gray values for each pen You can change the percentage value d...

Page 57: ...the first two cards Pen and Color Pen Scale Activate the check box if the pen widths are to be scaled with the drawing To avoid possible loss of information during the printout you must ensure that y...

Page 58: ...have not activated the clipping option Activate the option e g in case of a drawing that is exactly ISO A4 size to guarantee that it is printed on an A4 sheet and not on a printout with the next forma...

Page 59: ...es not normally have to be altered Nevertheless it is sometimes ad visable to ask the customer what step number per centimeter they are used to working with to guarantee plot consistency Furthermore i...

Page 60: ...the intended color saturation Which is why that when circle patterns are overlapped the cov ered areas cannot be as clearly identified as if two random pat terns are overlapped The recommended defaul...

Page 61: ...se special settings for your current print orders instead of File you must activate Custom at this point where you can then adjust your individual settings on the cards Pen and Color The settings have...

Page 62: ...PEN SETTINGS User Defined You can change the pen thickness and the grey shades apart from the black and white pens these settings are saved as pre sets RW 480 CLIENTS 62...

Page 63: ...bottom of the screen If you want to remove a pen you can set the pen widths as 0 or as the pen color White The standard values for the pen widths of the 16 Calcomp pens are given in the technical manu...

Page 64: ...the color Here too the changes are made directly us ing the keyboard Set all The Set all option allows you to set the pen attributes for all 16 pens simultaneously To do this first set the pen widths...

Page 65: ...oard Quit the window with OK and your changes will be saved If you do not wish to save your changes quit the window with Cancel or ESC In this window you can change the gray scale value which has been...

Page 66: ...d at the same time as a drawing is scaled To avoid the possible loss of infor mation when printed ensure that have set at least one minimum pen width if the drawing is to be reduced in size and at lea...

Page 67: ...can set the maximum thickness that the pen draws e g to prevent the drawn objects from overlapping when printed Setting the maximum pen widths on the other hand is less seldom neces sary Should one o...

Page 68: ...as if two random pat terns are overlapped The recommended default setting is therefore Random because you can achieve the best results Finally you can also select the gray value pattern Symmetric patt...

Page 69: ...al CALCOMP ONLINE REFERENCE MANUAL in the section Data Message Format The standard settings are Sync character 2 setting from 0 to 127 possible End character 0 setting from 0 to 31 possible Double Syn...

Page 70: ...a name to your new job Attention The extension ssl must be retained so as to guarantee that RW 480 PLOTBASE can recognize the job 3 Now you add new entries to the job Your have three possi ble option...

Page 71: ...able as an optional feature The file format DWF DWG DXF can only be used if if you have installed either a full version from AutoCAD series 2000 to 2006 or the DWF DWG DXF option Note RW 480 PLOTBASE...

Page 72: ...try new entries are always inserted at the end of the list 2 Keep the mouse cursor on the entry list and click the right hand mouse button 3 If the new entry is to be inserted in front of the marked e...

Page 73: ...Windows Explorer and arrange the two windows of RW 480 PLOTCLIENT WIN and Explorer so that they are po sitioned next to each other or on top of each other 2 Mark an entry in the entry list of RW 480...

Page 74: ...and only sets a reference to the already inserted file This approach of the program has two particular advantages for you On the one hand it saves space on your harddrive is the files are very large a...

Page 75: ...isted one after the other or use the SHIFT key To mark several entries that are not listed one after the other use the Ctrl Key as in Explorer After you have inserted or appended the entries adjust th...

Page 76: ...formation about general settings Pen Source Pen Scale Pattern Style etc which you can change in the job editor The tabs Drawing and Pens appear only if you open an HPGL or a Calcomp drawing file On th...

Page 77: ...Part II RW 480 WINPRINT RW 480 CLIENTS 77...

Page 78: ...lication menus File Print The RW 480 WINPRINT will be installed on the server PC where the server software RW 480 PLOTBASE is running On your cli ent PC you only have to share via network this printer...

Page 79: ...dd Printer and click on Next 3 Choose Network Printer and click on Next 4 Type printer name including complete network path of the server PC where RW 480 PLOTBASE is running or click Next to browse in...

Page 80: ...ws 95 Windows 98 Windows 98 SE Windows ME As soon as you have installed RW 480 WINPRINT as a network printer on your client PC you can now send a print out from a Windows program to RW 480 PLOTBASE Fi...

Page 81: ...er with Orientation You can choose between portrait and landscape Quality In this version there are hardly effects on the print out We rec ommend to use Production as standard setting Dithering This i...

Page 82: ...password has been entered For the password more than 32 characters can be accepted however it is recommended to use 4 to 32 characters Page Order Here you can choose from three options of pages to be...

Page 83: ...th following 32 bit operating systems Windows NT 4 0 Windows 2000 Windows XP As soon as you have installed RW 480 WINPRINT as a network printer on your client PC you can now send a print out from a Wi...

Page 84: ...e button Delete You can only delete your individual formats but not the standard default formats The eight buttons under Select Deselect can be used to adjust additional features for example whether y...

Page 85: ...e plotter by you you can protect it with a password To do so enter your password twice As soon as the plotter selects the print command for the corresponding job the plotter will demand the password s...

Page 86: ...hoose from three options of pages to be printed standard reverse auto standard The set entries are printed out in the order they are shown in the job editor 1 2 3 The order of the sheets in the result...

Page 87: ...ick on the question mark in the head of the row The mouse cursor changes into a question mark Now click on the function to which you have a question with the left hand mouse key A small popup window o...

Page 88: ...Part III RW 480 PLOTCLIENT HDI ADI RW 480 CLIENTS 88...

Page 89: ...2 AutoCAD LT 2002 AutoCAD 2004 AutoCAD LT 2004 AutoCAD 2005 AutoCAD LT 2005 or AutoCAD 2006 The print jobs can be sent to the RW 480 PLOTCLIENT WIN program or directly to the RW 480 PLOTBASE server pr...

Page 90: ...on I accept if you accept the licence agreements Click on I reject if you do not accept and want to stop in stallation 7 Read the information about the program and click on Next 8 Choose the setup ty...

Page 91: ...s Return once 8 Choose the option Parallel Port and press Return to con firm 9 Press Return to confirm the port name 10 Confirm your changes in the next step with Yes 11 Answer the question about chan...

Page 92: ...indow Preferences un der the menu point File Printer Setup 2 Open the window Add A Printer by clicking on New once 3 Choose option HP GL 2 Device and press OK to con firm 4 Choose option 4 HP DesignJe...

Page 93: ...ing If you use the HDI ADI Client your presets always only apply for the current print job If you take RW 480 PLOTCLIENT WIN you can add several other print jobs to your current print job and have the...

Page 94: ...K to confirm the default printer 8 In the next window Enter Plotserver IP enter the name or IP address of the PC where RW 480 PLOTBASE is running and press OK to confirm 9 In the window Enter Spool Di...

Page 95: ...onfiguration 14 Open Custom Properties to adjust specific driver settings as well as the settings for medium and resolution Server Name RW 480 PLOTCLIENT HDI ADI can be used for printing on several pl...

Page 96: ...et this dialog be Display each time Plot color merge control You have two options to choose By activating Colors merge all levels of your drawing will be merged At parts where two or more colors lie o...

Page 97: ...riginal the program obtains the format size from the original file of the drawing This is the presetting If you want to scale the drawing use scaling option in AutoCAD AutoCAD supports definition of c...

Page 98: ...rolls offered In addition you can also choose the automatic or manual options The automatic option means that the plotter itself selects a suitable roll which corresponds to the given format The manu...

Page 99: ...awings and depends on how much memory is available in your plotter s document server Consult your plotter manual for details if necessary Adjust the following settings User Name Also give the job a us...

Page 100: ...nt Here you define which pattern RW 480 PLOTCLIENT HDI ADI should use for the dither procedure when producing a printout with the RW 480 PLOTBASE There is a choice between Mixed Line Art and Graphic A...

Page 101: ...mmediately fol lowing successful print out Sample Print Activate this option if you want to check the quality of a print off Only the first set of copies will then be printed The print off of further...

Page 102: ...alogs are updated Select mode RW 480 PLOTCLIENT HDI ADI can be used in different modes Display this dialog When starting RW 480 PLOTCLIENT HDI ADI this dialog is always displayed for editing the job s...

Page 103: ...Part IV RW 480 PLOTCLIENT WEB RW 480 CLIENTS 103...

Page 104: ...g of the print processes in RW 480 PLOTBASE can be controlled via a status message Equally you can also have an e mail sent to obtain a message on successful job comple tion or if there are problems T...

Page 105: ...e necessary Java software package for this function The RW 480 PLOTCLIENT WEB also simultaneously picks up the de vice information on the connected plotter The following installation programs are deli...

Page 106: ...indows TIF viewer to be able to view tif files directly in the browser Select a suitable program for your operating system and start the installation Follow the instructions given by the installation...

Page 107: ...pages in the browser Select the menu command Start Pro grams RW 480 RW 480 RW 480 PLOTCLIENT WEB Admin on the server or enter the following configuration page address in the address line of your brow...

Page 108: ...lease contact your dealer or support technician User name Enter the name under which the new user is to use RW 480 PLOTCLIENT WEB Customer Here you can enter e g the complete name of the firm or pri v...

Page 109: ...W 480 PLOTCLIENT WEB via the web interface must be known to the system 3 Group IDs for several users must be strictly avoided as individual settings and job parameters can be lost 4 Access is possible...

Page 110: ...l paths which are given for RW 480 PLOTCLIENT WEB and for RW 480 PLOTBASE must show the identical folder Use of UNC path details can be used if RW 480 PLOTBASE and RW 480 PLOTCLIENT WEB are installed...

Page 111: ...ollowing Response Queue Path Enter the path for the response folder which is set up by RW 480 PLOTBASE The data in this file evaluates RW 480 PLOTCLIENT WEB to display the current queue status of the...

Page 112: ...on the check box Language Select a language for the configuration from the list filed The selected language will also be used for new users initially Each user can however also change the language ag...

Page 113: ...word admin The user ID and password can be set individually on the following page which you open by clicking on the administrator button Enter the user name and the password in the fields The pass wor...

Page 114: ...ame is issued automatically 4 Now choose the print parameters which are to apply for all entries drawings and documents For example you deter mine the format of the drawings or the medium on which the...

Page 115: ...cking on continue If you have entered wrong information simply click on restart The fields are now empty again and you can enter other information Settings for the job job parameters A job includes al...

Page 116: ...mation was assigned by the RW 480 PLOTCLIENT WEB administrator and cannot be changed Account This information is used for billing where this is to be produced If the administrator has released this fi...

Page 117: ...obtain a copy of the job Job flag sheet Activate the Print JobFlagsheet field by clicking on the check box if you want a cover sheet to be printed with all the informa tion in an overview You can ent...

Page 118: ...of a print Only the first set of copies is plotted Print out of further sets of copies is stopped so that you can examine the quality of the print You are then asked whether you wish to continue with...

Page 119: ...e for printing the summarized pages any paper transparency film and environment paper The choice depends on what you have put on the rolls of your plotter Media Source Select one of the shafts with th...

Page 120: ...nly apply for newly added entries If you change the print parameters in the middle they only apply for the new entries but not for the existing entries General print parameters Formats In this section...

Page 121: ...nd enter the required spacing for all side borders You can choose between the size units mm and inches Copies You can enter any number of copies between 1 and 999 to be printed by the job Media Source...

Page 122: ...anslucence has been scanned with mirror inversion to in crease the contrast Rotate Here you can set whether the drawing is to be rotated or not during plotting Rotations of 0 90 180 and 270 are possi...

Page 123: ...want a date in a stamp choose the macro with the same name If you select a macro it is inserted at the end of the stamp text If you want the macro to be inserted in the middle of the stamp text you c...

Page 124: ...is made in the pens list field HPGL Step size cm The standard is 400 steps per centimeter The RW 480 PLOTCLIENT WEB therefore enters 400 as a default value which does not normally have to be altered...

Page 125: ...ter lan guage of your plotter differs greatly from that of the HP DesignJet If you deactivate the function RW 480 PLOTCLIENT WEB looks for the drawing dimensions itself and thus guarantees that the wh...

Page 126: ...have to be altered Nevertheless it is sometimes advisable to ask the customer what step number per centimeter they are used to working with to guarantee plot con sistency Furthermore it can be necessa...

Page 127: ...rom 0 to 127 possible End character 0 setting from 0 to 31 possible Double Sync OFF Test sum OFF The following two examples serve as possible comparisons AutoCAD Sync character 22 End character 13 Dou...

Page 128: ...mm If you want to remove a pen you can enter the pen width as 0 or the pen color as white Gray The pen color is selected directly beneath Size Activate the re quired pen in the list above and enter th...

Page 129: ...Alternatively you can also click on the Browse button and the select a file from the opened dialog It is possible that the file selection has the file extension htm Change this to zip so that you can...

Page 130: ...and pass it directly on to RW 480 PLOTBASE There the print job is prepared for the print out Finally the print out is plotted on the plotter RW 480 To select such ZIP archives proceed in RW 480 PLOTC...

Page 131: ...in the window If you also want to add a single file click on Add file find the file in the file selection dialog and confirm with Open You can also delete individual files by clinking on the files co...

Page 132: ...y a copy on the RW 480 PLOTCLIENT WEB Server To change the print parameters for an entry proceed as follows 1 Open the entry list as described in the previous chapter 2 Select an entry from the list 3...

Page 133: ...ueue To see the current status you can either up date the page your self by clicking on refresh or you can activate automatic update by clicking on auto refresh In the latter case the page is al ways...

Page 134: ...t sheet tray Incomplete jobs Each job remains stored in RW 480 PLOTCLIENT WEB until it has been sent It is therefore possible that after logging on you will be given the opportunity of reediting a job...

Page 135: ...is running with in sufficient rights Access to the license file is only possible if the Apache Web Server is registered as the system service or as a service with user rights of a user of the adminis...

Page 136: ...Part V RW 480 PLOTCLIENT MAC RW 480 CLIENTS 136...

Page 137: ...ervice for UNIX 2 Change the settings so that the print service for UNIX automatically runs following each new start of the com puter To do this go to the Desktop and open My Com puter with by clickin...

Page 138: ...tion Set Up Printers to open the window Printer List 7 Click on the button Add to add the new printer 8 Now select the option IP Printing and choose option LDP LPR as Printer Type 9 Enter the IP addre...

Page 139: ...e print para meters MainOptions 1 Send a print job via the menu item File Print Open Main Options 1 via the drop down menu General There you can alter the following settings Scale to format Select the...

Page 140: ...mum paper or medium usage because it produces the least waste If on the other hand you want the print out to always be cut in a standard format no matter how much paper remains unprin ted activate For...

Page 141: ...is output at the front JobOptions In addition to the MainOptions you have four other general options that you can use to define the print job parameters Sample print Activate this option if you want t...

Page 142: ...Part VI RW 480 PLOTCLIENT LPR FTP RW 480 CLIENTS 142...

Page 143: ...80 WINPRINT check that the printer driver has been released or enabled and check the spool folder as follows 1 Open the printer window via Start Settings Printers 2 Use the right hand mouse key to ope...

Page 144: ...with your print parameters first then send the graphic file Oth erwise there is a risk that RW 480 PLOTBASE begins to print your file before it has received your own print pa rameters for the print C...

Page 145: ...t service For SuSE V6 4 rclpd restart Print jobs on UNIX using lpr If you have entered all the settings described above you can use the lpr command as follows to send print jobs to the RW 480 PLOTBASE...

Page 146: ...the ftp command as follows to send print jobs to RW 480 PLOTBASE via the RW 480 WINPRINT 1 Open the Prompt on the Windows computer of RW 480 PLOTBASE 2 Change to the folder containing the files to be...

Page 147: ...t you have to first send the CFG file which must have the same name as the graphic file and then send the graphic file itself Attention Always send the CFG or SSL file with your print parameters first...

Page 148: ...turn key 7 Enter the following command if you want to print a file If you want to print several files proceed with Item 8 For one file the command is put filename put graphics tif 8 If you want to pri...

Page 149: ...with your print parameters first then send the graphic file Oth erwise there is a risk that RW 480 PLOTBASE begins to print your file before it has received your own print pa rameters for the print CF...

Page 150: ...Part VII Appendix RW 480 CLIENTS 150...

Page 151: ...dices 44 HPGL 2 19 20 71 clipping 57 colors 56 dither mode 59 fill pattern 60 font path 59 ignore pen size 58 misc 57 pen setting 58 pens 54 scale pens 57 sizes per cm 59 Installation PLOTCLIENT HDI A...

Page 152: ...ormats 139 installation 137 invert 140 media type 140 mirror 139 rotate 139 sample print 141 PLOTCLIENT WEB admin password 113 auto refresh 111 Calcomp 126 clipping 125 collate 117 configuration 107 c...

Page 153: ...UNC 27 user name 34 working folder 27 Program Quit 16 Start 16 RLC 19 20 71 Stamp configure 46 delete 47 edit 47 font 50 frame 49 inverting 49 logo 52 macros 51 mirror 48 number of stamps 46 opaque 4...