All wires are positioned away from high-temperature and high-voltage parts, and, if removed for
servicing, they must be retuned precisely to their original positions.
5. LAMP
Be very careful of the lamp because it generates high heat while it is used at high voltage. When
replacing the bulb, make sure it is cool enough.
6. LENS
Do not look into the lens during projection. This is important to avoid damage to the eyes.
7. SERVICING
At the time of repair or inspection services, use an earth band (wrist band), without fail.
8. RUN A COMPLETE SAFETY CHECK AT THE COMPLETION OF SERVICING
After completion of servicing, confirm that all screws, parts, and wiring, removed or disconnected
for servicing, have been returned to their original positions. Also examine if the serviced sections
and peripheral areas have suffered from any deterioration as a result of servicing. In addition,
check insulation between external metallic parts and blades of walloutlet plugs. This examination is
indispensable in confirming complete establishment of safety.
(Insulation check)
Pull out a plug from a wall outlet to disconnect the connection cable. Then turn on the POWER
switch. Use a 500V megger (Note 2) and confirm that the insulation resistance is 1M or more
between each terminal of the plug and exposed external metal (Note 1). If the measured value is
below the specified level, then it is necessary to inspect and fix the set.
(Note 1)
Exposed external metal....RGB input terminals, control terminals, etc.
(Note 2)
If a 500V megger is not available for an unavoidable reason, then use a circuit tester or the like for
inspection.
2
Summary of Contents for PJ WX5350
Page 1: ...Model Rigel PJ1 nx nw Machine Codes Y015 Y016 Field Service Manual 6 January 2012...
Page 2: ......
Page 10: ...8...
Page 20: ...1 Product Information 18...
Page 25: ...Installation Requirements 23...
Page 26: ...2 Installation 24...
Page 34: ...Filters 1 Remove the Filter cover 2 Remove the Filters 3 Replacement and Adjustment 32...
Page 38: ...Rear Panel and Speaker 1 Top cover p 33 3 Replacement and Adjustment 36...
Page 55: ...3 Remove the bracket A 2 4 Remove the screw 1 5 Remove the barrier Parts Replacement 53...
Page 57: ...PSU Fan 1 Remove the Exhaust fan cover p 51 Parts Replacement 55...
Page 135: ...For Audio Does not output sound from the speaker Troubleshooting Guide 133...
Page 138: ...Service Information Reset Not related to the menu mode 5 Troubleshooting 136...
Page 143: ...Model Rigel PJ1 Machine Codes Y015 Y016 Appendices 6 January 2012...
Page 145: ...2...
Page 153: ...MEMO 10...
Page 154: ...MEMO 11...
Page 155: ...MEMO 12 EN...