Service Menu
SM 5-25
M095/M096/M099/M100
Syste
m
Ma
in
te
na
n
ce
Ref
eren
ce
Horiz Bypass
Tray
Adjusts the horizontal registration for the bypass
tray. If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Vert Bypass
Tray
Adjusts the vertical registration for the bypass tray.
If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Horiz.Dup Back
Adjusts the horizontal registration for the back side
in duplex mode. If the machine settings are reset
to the factory defaults, this value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Vert.Dup Back
Adjusts the vertical registration for the back side in
duplex mode. If the machine settings are reset to
the factory defaults, this value does not change.
[-15 to 15 / 0 (Default) / 1 mm/step]
Init Engine
EEPROM
This clears all counters except "Full Color" and "Black and White" in
the total counter.
When you execute "Init Engine EEPROM", the engine EEPROM is
initialized.
Turn the machine power off/on after you change this setting.
Model
Displays only
PE-P2a / MF3a
PE-P2c / MF3c
Displays the current model in a dropdown list.
Do not change this setting (Designed for Factory Use).
Brand ID
00* – 7F
Displays the current brand ID number.
Do not change this setting (Designed for Factory Use).
Maintenance ID
00* – 7F
Displays the current maintenance ID number.
Do not change this setting (Designed for Factory Use).
Summary of Contents for M095
Page 1: ...M095 M096 M099 M100 SERVICE MANUAL ...
Page 2: ......
Page 6: ......
Page 16: ......
Page 17: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 18: ......
Page 29: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Page 30: ......
Page 34: ......
Page 35: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 36: ......
Page 38: ......
Page 39: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Page 40: ......
Page 92: ...Paper Exit M095 M096 M099 M100 4 52 SM 4 Remove the four exit guides C and gear D bushing x 1 ...
Page 106: ...Electrical Components M095 M096 M099 M100 4 66 SM 6 Fusing stripper pawl solenoid B x 2 ...
Page 112: ...Electrical Components M095 M096 M099 M100 4 72 SM 7 PSU assembly E x 4 x 7 8 PSU F x 4 ...
Page 138: ......
Page 139: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None ...
Page 140: ......
Page 184: ......
Page 185: ...ENVIRONMENTAL CONSERVATION REVISION HISTORY Page Date Added Updated New None ...
Page 186: ......
Page 192: ......
Page 193: ...M095 M096 M099 M100 SERVICE MANUAL APPENDICES ...
Page 194: ......
Page 196: ......
Page 197: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Page 198: ......
Page 224: ......
Page 226: ......
Page 228: ......
Page 230: ......
Page 236: ......