Service Call Conditions
M095/M096/M099/M100 5-18
SM
SC 6xx (Communication and Other Error)
669
EEPROM Error
An unexpected value exists in the initialization flag of the EEPROM
EEPROM not initialized
Defective
EEPROM
1. Initialize
the
EEPROM.
2. Replace
the
EEPROM.
3. Replace
the
EGB.
690
GAVD Communication Error
The ID of the GAVD is not identified during initialization.
The chip ID of the GAVD cannot be detected by the machine at power-on.
Defective
EGB
1. Replace
the
EGB.
Summary of Contents for M095
Page 1: ...M095 M096 M099 M100 SERVICE MANUAL ...
Page 2: ......
Page 6: ......
Page 16: ......
Page 17: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Page 18: ......
Page 29: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Page 30: ......
Page 34: ......
Page 35: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Page 36: ......
Page 38: ......
Page 39: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Page 40: ......
Page 92: ...Paper Exit M095 M096 M099 M100 4 52 SM 4 Remove the four exit guides C and gear D bushing x 1 ...
Page 106: ...Electrical Components M095 M096 M099 M100 4 66 SM 6 Fusing stripper pawl solenoid B x 2 ...
Page 112: ...Electrical Components M095 M096 M099 M100 4 72 SM 7 PSU assembly E x 4 x 7 8 PSU F x 4 ...
Page 138: ......
Page 139: ...SYSTEM MAINTENANCE REFERENCE REVISION HISTORY Page Date Added Updated New None ...
Page 140: ......
Page 184: ......
Page 185: ...ENVIRONMENTAL CONSERVATION REVISION HISTORY Page Date Added Updated New None ...
Page 186: ......
Page 192: ......
Page 193: ...M095 M096 M099 M100 SERVICE MANUAL APPENDICES ...
Page 194: ......
Page 196: ......
Page 197: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Page 198: ......
Page 224: ......
Page 226: ......
Page 228: ......
Page 230: ......
Page 236: ......