MASTER EJECT
C262/C265 6-38
SM
Master Box Full Detection Mechanism
As explained above, the pressure plate motion range narrows as the ejected
masters build up in the box. The stopping position of the pressure plate therefore
gets closer to the home position.
When the pressure plate cannot travel past the master box full position from the
master eject ready position, this means that the master box is full.
In this case, the home position sensor [A] remains actuated as shown on the right.
The home position sensor status changes (from the master eject ready position):
on
⇒
off
⇒
on
⇒
off
⇒
on, and stays on. This means the master box is full and the
operation panel displays a message.
C262D028.WMF
Master Box Full
Position
[A]