FIRMWARE
UPDATE
SM 5-59
C262/C265
Service
Tables
5.5.4 ERRORS DURING FIRMWARE UPDATE
If an error occurs during a download, an error message will be shown in the first
line. The error code consists of the letter “E” and a number (“E20”, for example).
Error Message Table
NO. MEANING
SOLUTION
20
Cannot map logical address
Make sure the SD card is installed correctly, or use a
different SD card.
21
Cannot access memory
HDD connection not correct, or replace the hard disk.
22 Cannot
decompress
compressed data
The ROM data on the SD card is not correct, or data
is damaged.
23
Error occurred when ROM
update program started
Controller program defective. If the second attempt
fails, replace the ACU board.
24
SD card access error
Make sure the SD card is installed correctly, or use a
different SD card.
31
Data incorrect for continuous
download
Install the SD card with the remaining data necessary
for the download, then re-start the procedure.
32
Data incorrect after download
interrupted
Do the recovery procedure for the module, then
repeat the installation procedure.
33
Incorrect SD card version
The firmware on the SD card is not correct, or data is
damaged.
34
Module mismatch - Correct
module is not on the SD card
The data on the SD card is not correct. Get the
correct data (Japan, Overseas, OEM, etc.) then
install again.
35
Module mismatch – Module on
SD card is not for this machine
SD update data is not correct. The data on the SD
card is for a different machine. Get the correct data
then install again.
36
Cannot write module – Cause
other than E34, E35
SD update data is not correct. The data on the SD
card is for a different machine. Get the correct data
then install again.
40
Engine module download failed
Replace the data for the module on the SD card and
try again, or replace the ECU board.
42
Operation panel module
download failed
Replace the data for the module on the SD card and
try again, or replace the operation panel.
44
Controller module download
failed
Replace the data for the module on the SD card and
try again, or replace the ACU board.
The write-protect switch on the SD card is ON. Turn it
off.
45
PS module download failed
Replace the data for the module on the SD card.
Replace the ACU.
Replace the PS module
Summary of Contents for LDD250
Page 1: ...LDD280 C262 LDD250 C265 SERVICE MANUAL 002648MIU rev 05 31 06...
Page 2: ......
Page 3: ...C262 C265 SERVICE MANUAL...
Page 4: ......
Page 5: ...C262 C265 SERVICE MANUAL 002648MIU...
Page 6: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 24: ......
Page 28: ...SPECIFICATIONS...
Page 29: ......
Page 34: ...INSTALLATION...
Page 35: ......
Page 43: ...INSTALLATION PROCEDURE C262 C265 1 8 SM C262I044 WMFF C262I046 WMFF...
Page 70: ...PREVENTIVE MAINTENANCE...
Page 71: ......
Page 74: ...REPLACEMENT AND ADJUSTMENT...
Page 75: ......
Page 233: ...TROUBLESHOOTING...
Page 234: ......
Page 259: ...SERVICE TABLES...
Page 260: ......
Page 321: ...DETAILED SECTION DESCRIPTIONS...
Page 322: ......