TROUBLESHOOTING PROCEDURES
6-3
Trouble-
shooting
6.4 TROUBLESHOOTING
PROCEDURES
There are two types of troubleshooting procedure.
•
For user-visible error conditions that the user could not clear up
•
For technician level error conditions
6.4.1 USER-VISIBLE ERROR CONDITIONS
ADF Interlock Switch Open
Symptom:
The problem cannot be solved with the procedures in the user’s manual.
Possible Causes:
•
Defective ADF interlock switch
•
Damaged cable between the ADF interlock switch and the PSU
Procedure:
Does 24 volts come to the ADF cover interlock switch?
Yes
No
Is the cable damaged?
Yes
No
Replace the PSU.
Replace the cable.
Replace the ADF interlock switch.