SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC547-01
D
Zero-crossing error (adhered relay contact)
When the fusing relay is in an OFF state, a "zero-crossing interrupt
request" occurs in 50 ms.
Damaged fusing relay (adhered contact)
• Turn the main power OFF and then ON.
• Replace the harness.
• Replace the PC board.
• Replace the PSU.
SC547-02
D
Zero-crossing error (bad relay contact)
If a "zero-crossing interrupt request" does not occur when the fusing relay
is in an ON state, an error results.
- Damaged fusing relay (open contact)
- Failed fusing relay drive circuit
- PSU fuse (24VS) blown
• Turn the main power OFF and then ON.
• Replace the harness.
• Replace the Engine Board.
• Replace the PSU.
• Replace the fuse.
SC547-03
D
Zero-crossing error (low frequency error)
The number of zero-crossing interrupts does not reach a certain value in
500 ms.
The frequency of the commercial power supply is unstable.
• Turn the main power OFF and then ON.
• Check the commercial power supply.
• Replace the harness.
• Replace the Engine Board.
• Replace the PSU.
6. Troubleshooting
150
Summary of Contents for Gim-MF1a
Page 1: ...Model Gim MF1a b Machine Code M172 M173 Field Service Manual September 2014...
Page 2: ......
Page 32: ...2 Installation 30...
Page 46: ...2 Operation Panel A x 5 4 Replacement and Adjustment 44...
Page 105: ...2 Rear Cover Switch A x 1 Hook Electrical Components 103...
Page 122: ...5 Operation Panel page 43 Operation Panel 4 Replacement and Adjustment 120...
Page 125: ...Service Program Mode 123...
Page 184: ...6 Troubleshooting 182...
Page 192: ...MEMO 190...
Page 193: ...MEMO 191...
Page 194: ...MEMO 192 EN...
Page 195: ...Model Gim MF1a b Machine Code M172 M173 Appendices September 2014...
Page 196: ......
Page 214: ...1 Appendices Specifications 18...
Page 299: ...MEMO 103...
Page 300: ...MEMO 104 EN...